CHAPTER 1 SCREEN OPERATIONS
5. Diagnosis Screens
I
– 292
(2) Menus
Menu
Details
Type
Reference
Continu
samplng
Sampling starts and the waveform is continuously displayed.
If this menu is selected again, the menu highlight returns to
normal, and the sampling is canceled.
If a trigger is set, the waveform will not appear until the trigger
is input. Even if another screen is displayed during sampling,
the sampling will not stop.
If a trigger is not set and another screen is displayed during
continuous sampling, the sampling will end at that point.
A
5.8.2 Carrying
out continuous
sampling
Single
samplng
Sampling starts and the waveform for the sampled buffer is
displayed.
If another screen is displayed during single sampling, the
sampling will end at that point.
The sampling ends when the sampled buffer is filled, and the
menu highlight returns to normal.
The trigger setting is invalid.
A
5.8.3 Carrying
out single
sampling
<-
Scroll
The area displaying the waveform is scrolled 1/4 of a screen
to the left.
Note that this menu cannot be used during sampling.
C
−
->
Scroll
The area displaying the waveform is scrolled 1/4 of a screen
to the right.
Note that this menu cannot be used during sampling.
C
−
Wave
clear
The waveform displayed on the screen is erased.
Note that this menu cannot be used during sampling.
C
−
Display
mode
Set the channel of the waveform to be displayed. Up to three
channels can be set.
The cursor will move to the display mode field when this
menu is pressed.
C
5.8.1 Setting the
channel of the
waveform to be
displayed
Re-disp
This redisplays the waveform displayed before the screen
was changed.
Note that this menu cannot be used during sampling.
(Note)
If the vertical scale, horizontal scale, base line and
offset conditions have been changed, the waveform
will be redisplayed using the changed conditions.
However, the other condition changes will not be
handled.
C
−
To cond
set
This changes to condition setting screen (screen for setting
conditions such as sampling, trigger data, waveform display).
C
5.7 Condition
Setting screen
(V Anlyz
condition
screen)
Downloaded from
Содержание MELDAS 600M Series
Страница 1: ...CNC 600M Series INSTRUCTION MANUAL BNP B2237J ENG Downloaded from ManualsNet com search engine ...
Страница 15: ...CHAPTER 1 SCREEN OPERATIONS Downloaded from ManualsNet com search engine ...
Страница 333: ...CHAPTER 2 MACHINE OPERATIONS Downloaded from ManualsNet com search engine ...
Страница 386: ...CHAPTER 3 MAINTENANCE Downloaded from ManualsNet com search engine ...
Страница 442: ...CHAPTER 4 APPENDICES Downloaded from ManualsNet com search engine ...