CHAPTER 4 APPENDICES
Appendix 3. Alarm Messages
IV
– 29
No. Abbrev.
Message
Details
Cancel-
lation
method
SV0077
Pwr sply power module
overheat
Overheating of the power module (IPM) was
detected.
PR
SV0088 WD
Watch dog
The servo amplifier software processing failed to
finish within the specified time.
AR
SV1001
AMP
unequipped
The servo/spindle amplifier is not connected.
Or, the axis No. setting for the servo/spindle
amplifier is incorrect.
PR
SV1002
Illegal servo amp
A spindle amplifier is connected to the servo
axis.
Or, a servo amplifier is connected to the spindle.
Check the axis No. of the spindle specification
parameters.
PR