CME-1

All specifications are subject to change without notice.

    Features

• Medical safety standard (IEC60601-1) approved.
• Leakage current 0.3mA or less (at 265VAC)
• EMI class B approved.

CME 

SERIES

    Product line up

Single Output 150W - 240W

    Applications

MED

Model

CME150-24

CME240P-24

Output voltage

24V

24V

Max output current

6.3A

10A

Max output power

151.2W

240W

Peak output current

7.5A

20A

Peak output Power

180W

480W

UL60601-1

CSA 22.2

No.601-1, M90

(cUL-certified)

EN60601-1

Y

E

A

R

S

warranty

3

This  means  that,  in  conformity  with  EU  Directive  2002/95/ 
EC, lead, cadmium, mercury, hexavalent chromium, and spe-
cific bromine-based flame retardants, PBB and PBDE, have 
not been used, except for exempted applications.

    Conformity to RoHS Directive

Содержание CME Series

Страница 1: ...E240P 24 Output voltage 24V 24V Max output current 6 3A 10A Max output power 151 2W 240W Peak output current 7 5A 20A Peak output Power 180W 480W UL60601 1 CSA 22 2 No 601 1 M90 cUL certified EN60601...

Страница 2: ...Standards Safety Standards 12 Approved by UL60601 1 EN60601 1 Built to meet UL60950 1 CSA60950 1 EN60950 1 and DENAN PFHC Built to meet EN61000 3 2 EMI 13 Built to meet EN55011 EN55022 B FCC ClassB VC...

Страница 3: ...1 1 J S T 9 11 HAND CRIMPING TOOL YC 160R MANUFACTURER J S T 37 1 80 1 70 0 5 Ground the FG to the safety ground of the equipment or device There must be at least 4 mm gap between the end of the print...

Страница 4: ...romagnetic field erosive gas etc or any environment where conductive foreign substance may enter Do not operate and store this unit at the condition of condensation In such case waterproof treatment i...

Страница 5: ...EN60601 1 2 EMC but EMC test data is available from TDK LAMBDA Corporation Special Instructions for IEC EN UL 60601 1 1 Terminal Explanation CME150 CME240P 1 L AC input terminal pin 1 of CN1 Live lin...

Страница 6: ...erload or dead short conditions for more than 30 seconds which could result in damage or insulation failure Output Ripple Noise The standard specification for maximum ripple value is mea sured accordi...

Страница 7: ...ge load after derating by vari ous Mounting and Ta Examples of peak load derating calculated by above formula Actual Io Average Load Io A Ip A max D max Im A Io A 100 10 20 35 0 3 92 9 55 90 9 20 30 4...

Страница 8: ...lso use all 4 mounting holes for the unit installation The vibration spec is the value taken when the unit is raised by 8mm spacers And allowable area by metal pieces is 9mm from each PCB corners Refe...

Страница 9: ...igh braking capac ity fuse when selecting the external fuses that are to be used on input line Surge current flows when line turns on There fore use slow blow fuse or time lug fuse Do not use fast blo...

Страница 10: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information TDK Lambda CME240P 24...

Отзывы: