CME-2
CME
・
All specifications are subject to change without notice.
MODEL
ITEMS/UNITS
CME150-24
CME240P-24
Input
Voltage Range
(*3)
V
AC85 - 265
Frequency
(*3)
Hz
47-63
Power Factor (100/200VAC)(Typ) (*2)
0.99 / 0.95
Efficiency (Typ)
(*2)
%
82
80
Current (100/200VAC)(Typ) (*2) A
2.0 / 1.0
3. 2/ 1.6
Inrush Current (100/200VAC)(Typ) (*4) A
14 at 100VAC, 28 at 200VAC, Ta=25
°C
, Cold Start
Leakage Current (265VAC) (*10) mA
Less than 0.3
Less than 0.22
Output
Nominal Voltage
VDC
24
Maximum Current
A
6.3
10
Maximum Peak Current (*1) A
7.5
20
Maximum Power
W
151.2
240
Maximum Peak Power
(*1)
W
180
480
Maximum Line Regulation (*5,*6) mV
96
Maximum Load Regulation (*5,*7) mV
150
192
Temperature Coefficient
Less than 0.02% /
°C
Maximum Ripple & Noise 0<Ta<60
°C
(*5) mVp-p
150
240
Maximum Ripple & Noise -10<Ta<0
°C
(*5) mVp-p
180
360
Hold-up Time (Typ)
(*2)
ms
20
Voltage Adjustable Range (*10) VDC
21.6-26.4
21.6-28.8
Function
Over Current Protection (*8) A
7.87 -
20.5 -
Over Voltage Protection (*9) VDC
27.6 - 32.4
30.0 - 35.0
Remote ON/OFF Control
-
Parallel Operation
-
Series Operation
Possible
Environment
Operating Temperature (*11)
°C
-10 to +60
°C
(-10 to +50°C:100%, +60°C:80%)
-10 to +60
°C
(-10 to +45°C:100%, +60°C:60%)
Storage Temperature
°C
-30 to +85
°C
Operating Humidity
%RH
30 - 90 (No dewdrop)
Storage Humidity
%RH
10 - 95 (No dewdrop)
Vibration
At no operating, 10-55Hz (Sweep for 1min.)
19.6m/s² Constant, X,Y,Z 1hour each
Shock (In package)
Less than 196.1m/s²
Cooling
Convection Cooling
Isolation
Withstand Voltage
Input - FG : 2kVAC (20mA), Input - Output : 4kVAC (20mA)
Output - FG : 500VAC (100mA) for 1min.
Isolation Resistance
More than 100MΩ at 25
°C
and 70%RH, Output - FG : 500VDC
Standards
Safety Standards
(*12)
Approved by UL60601-1,EN60601-1
Built to meet UL60950-1,CSA60950-1,EN60950-1, and DENAN
PFHC
Built to meet EN61000-3-2
EMI
(*13)
Built to meet EN55011 / EN55022-B, FCC-ClassB, VCCI-B
Immunity
Built to meet EN61000-4-2, -3, -4, -5, -6, -8, -11
Mechanical
Weight (Typ.)
g
500
800
Size (W×H×D)
mm 80 x 40 x 208 (Refer to Outline Drawing) 105 x 50 x 242 (Refer to Outline Drawing)
Specifications
*Read instruction manual carefully, before using the power supply unit.
(*1) Operating period at peak output current is less than 10sec.
Input voltage < 95V : Duty < 0.2
Input voltage > 95V : Duty < 0.35
(Average output power and current is less than Maximum output power and current)
For peak load derating method, please refer to the instruction manual for details.
(*2) At 100/200VAC, Ta=25°C and maximum output power.
(*3) For cases where conformance to various safety specs (UL,CSA,EN) are required, to be described as100 - 240VAC, 50/60Hz on name plate.
(*4) Not applicable for the in-rush current to Noise Filter for less than 0.2ms.
(*5) Please refer to Fig. A for measurement of line & load regulation and ripple voltage.(Measure with JEITA RC-9131 probe)
(*6) 85 - 265VAC , constant load.
(*7) No load - Full load (maximum power), constant input voltage.
(*8) Constant current limit and hiccup with automatic recovery. Avoid to operate at overload or dead short condition for more than 30 seconds.
(*9) OVP circuit will shut down output, manual reset.(Line recycle)
(*10) Measured by the each measuring method of IEC, UL, CSA, EN and DENAN(at 63Hz).
(*11) At standard mounting.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- For other mountings, refer to derating curve.
(*12) As for DENAN, built to meet at 100VAC.
(*13) No load - Full load (maximum power), constant current and input voltage.