Chapter 9 Functions
9-130
(b) CAM control mode setting
1) Control method
Set the form of CAM repeat pattern. “Repeat mode” and “Increase mode” may be set.
▪ Repeat (Two-way mode)
Execute round-trip motion repeatedly in the range already set from starting position of sub axis to ending
position according to the position of main axis in 1 rotation.
When CAM data is created in repeat, the ending position of the last step of sub axis user last set must be
set as 0.
<CAM data>
Position
Ending
position of
Sub axis
Position of main axis
Position in 1rotation
of main axis
Position of sub axis
Ending
position of
main axis
Time
Time
Time
0
1 rotation of main axis
1 cycle
1 cycle
1 cycle