Chapter 6 Command
6-72
6.3.46 Set Step Data of POINT Start (Command: XPWR)
(1) Program
(2) Description
Device
Description
M00031
axis1 Point Start Step Data Setting Input
M00032
axis1 Point Start Input
U02.00.0 axis1 ready
D00000.0 axis1 Operating State
D00000.1 axis1 Error State
D03000
Point Start Step Data Setting Leading Device
No.
Comman
d
XPWR
POINT Start Step Data Setting
Operand
OP1
Slot
Constant
WOR
D
Slot No. installed with positioning module
OP2
Axis
PMLK,constant,D,Z,R,ZR WOR
D
Command axis
XBF-PN04B: 1axis~4axis
XBF-PN08B:1axis~8axis
OP3 Device
PMLK,D,Z,R,ZR
WOR
D
Leading No. of device with POINT Start Step
Data
OP3 Data
No.
PMLK,constant,D,Z,R,ZR WOR
D
Data No. to save (1 ~ 20)
※
PMLK means P, M, L and K areas.
(a) This is the command that sets step which set on device of point step area of command axis.
(b) Point start won’t be executed by only point start step data setting command. Refer to the previous page
about PST command.
(c) It is able to set maximum 20 point start step.