Chapter 6 Command
6-56
(f) The above sample program, is to change the input signal parameters of one axis to the value stored in
D02100. For D02100 = h0123, the input signal A "3: External start", the input signal B is "2: Switching
position / torque control", the input signal Z is 1: Switching Speed / position control "is set in the function
you.
6.3.36 Input signal parameter – Switching torque of external position/torque control
teaching (Command : XSEST)
(1) Program
(2) Description
Device
Description
M00049
1axis Switching torque of external
position/torque control teaching
U02.00.0 1axis operation ready
D00000.0 1 axis signal in operation
D02100
Parameter value
Command
XSEST
Switching torque of external position/torque
control teaching
Operand
OP1
Slot
Constant
WO
RD
Slot No. installed with positioning module
OP2
Axis
PMLK,Constant,D,Z
,R,ZR
WO
RD
Command axis
XBF-PN04B: 1axis~4axis
XBF-PN08B:1axis~8axis
OP3 Torque value
PMLK,Constant,D,Z
,R,ZR
INT
Switching position/Torque control torque
value to change
OP4
Setting
method
PMLK,Constant,D,Z
,R,ZR
WO
RD
0: RAM, 1: ROM
※
PMLK means P, M, L and K areas.
(a) It is a command to change to the
‘
external location / torque control switching torque
’
setting (OP3) in
the parameter of the input signal of the axis. In case of setting method(OP4), If you have a set of RAM,
changed value is maintained during power on. If you have a set of ROM, changed value is maintained
during power off.
(b) Input signal parameters of the positioning module, because they are stored in the MRAM, the number of
executions of the ROM of setting there is no limit.
(c) Command of Switching torque of external position/torque control teaching, if the axis is in operation can not
be performed.
(d) Setting range of torque values are as follows.
-32768 % ~ 32767 %
(f) The above sample program, is to change the input signal parameters of one ax is to the value stored in
D02100. If D02100 = is 5, the torque value of the switching of the external position / torque control is set to
5%.
Содержание XBF-PN04B
Страница 1: ...Programmable Logic Controller Positioning Module EtherCAT XGB Series XBF PN04B XBF PN08B ...
Страница 626: ...Chapter 9 Functions BPS37 setup RS232 and PC connection BPS37 option board LED 9 193 ...
Страница 628: ...Chapter 9 Functions c Execute BPS37 set up program and enter the setting values as follows 9 195 ...
Страница 796: ...Appendix3 Dimension A3 1 Appendix 3 Dimension Appendix 3 1 Dimension of XBF PN04B PN08B ...