Chapter 3 Operation Order and Installation
3-1
Chapter 3 Operation Order and Installation
3.1 Operation Order
▶
Here describes the Operation order in case of positioning operation by positioning module.
External emergency stop signal
External upper limit signal
External lower limit signal
Home signal
DOG signal
External Dec. Stop (or position/speed control switching) signal
Reading/Writing servo parameter and servo tuning are
available by XG-PM
Allocate the axis number to each servo by using
XG-PM
Connect the motor and external signal to the servo
Write the servo parameter in the XG-PM and download it to servo
Connect Ethernet communication cable between positioning module
and servo, and between servos
Write the operation data and parameter of positioning module in
the XG-PM and download it to the module
Set up the servo axis and establish communication between Servo
and postioning module
Specify the number of axis to be connected
Specify the servo type and capacity
Install the XG5000 and XG-PM on the PC
Mount the positioning module on the base
Specify positioning method and control unit
Turn the PLC on
Connect the communication cable between USB ports (RS-232C)
of PC and PLC CPU module
End
Start
Execute a test run by using XG-PM
Write the program for positioning operation through XG5000
Start the positioning operation
Max. Communication distance: 100m
Communication cable: STP cable
Check whether RDY LED is ON or not
Basic
parameter,
extended
parameter,
manual
operation parameter, common parameter, operation
data
Check the operation status and modify the module
parameter and servo parameter
Содержание XBF-PN04B
Страница 1: ...Programmable Logic Controller Positioning Module EtherCAT XGB Series XBF PN04B XBF PN08B ...
Страница 626: ...Chapter 9 Functions BPS37 setup RS232 and PC connection BPS37 option board LED 9 193 ...
Страница 628: ...Chapter 9 Functions c Execute BPS37 set up program and enter the setting values as follows 9 195 ...
Страница 796: ...Appendix3 Dimension A3 1 Appendix 3 Dimension Appendix 3 1 Dimension of XBF PN04B PN08B ...