Chapter 7 Function Block
7-34
7.5.9. Restart (XPM_RSTR)
Form of Function Block
Description
DONE
REQ
BASE
SLOT
STAT
BOOL
BOOL
USINT
USINT
UINT
AXIS
USINT
Input
REQ : Request for execution of function block
BASE : Set the base no. with module
SLOT : Set the slot no. with module
AXIS : Axis to command
XBF-PN04B:1~4, XBF-PN08B:1~8
Output
DONE : Maintain 1 after first operating
STAT : Output the error no. in operation
(1) Give “Restart” command to the axis of positioning module designated by BASE (Base no. of Positioning
module) and SLOT (Slot no. of Positioning module).
(2) This command is used when restarting the axis which stops by EMG stop command. If this command is
executed, the axis operates again with previous operating information.
(3) If you start the axis with commands other than “Restart” after it stops with DEC. stop, “Restart” will not be
executed
(4) You can set axis to command in “AXIS” and the following value is available. If you set other values, error code
“6” appears.
XBF-PN04B:1~4, XBF-PN08B:1~8
(5) For detailed information on “Restart”, refer to “9.2.20. Restart”.
(6) If the command changing current operation is executed except for DEC. stop, “Restart” will not be executed.
(7) It is impossible to execute the “Restart” in case of continuous operation, circular interpolation, home and all
operation of sub axis.
Содержание XBF-PN04B
Страница 1: ...Programmable Logic Controller Positioning Module EtherCAT XGB Series XBF PN04B XBF PN08B ...
Страница 626: ...Chapter 9 Functions BPS37 setup RS232 and PC connection BPS37 option board LED 9 193 ...
Страница 628: ...Chapter 9 Functions c Execute BPS37 set up program and enter the setting values as follows 9 195 ...
Страница 796: ...Appendix3 Dimension A3 1 Appendix 3 Dimension Appendix 3 1 Dimension of XBF PN04B PN08B ...