Chapter 6 Command
6-23
main axis, axis1 (subordinate axis) is operated depending on the designated ratio between main axis (OP3)
and sub axis(OP4).
(b) If speed sync. ratio (sub axis ratio / main axis ratio) is positive integer, sub axis operation turns main axis
direction, if not positive integer, it turns the opposite of main axis direction.
(c) For example, if main axis ratio is 3, sub axis ratio is 2 and target position is 1,000,000, when main axis moves
by 3000, sub axis moves 2000. It stops by where position of main axis is at 1,000,000.
(d) For the detail description about speed sync., refer to “9.4.1 Speed Synchronous Start Control”.
(e) D device signal (axis1 in Operation, etc) which used in the example above is an assumption that saving the
axis state value in D device area with XSRD command.
Содержание XBF-PN04B