Chapter 8 Program
8-89
(4) Servo Off
(a) Condition for servo off
Condition to execute Servo off command (XPM_SVOFF)
(b) Axis ready
If communication between the positioning module and the servo driver is normal, corresponding signal will be
on. In the example program, if the condition for “Servo off” is on, it will gives “Servo off” command. You can
remove the axis not connected
(c) Address of Positioning Module
Before operation, you need t o configure its position by numbers. In this example, Positioning Module is
installed at the 3 slot.
(d) Axis of operation
If you command each axis, need to set Axis of command execution. XBF-PN04(8)B can control max. 4(8) axes.
Axis of command execution1~4(8) means axis1~axis4(8).
(e) State of Operation complete
If function block is completed without error, “1” will be outputted and m aintain “1” until the next operation. If
error occurred, “0” will be outputted.
(f) Error State
This is the area that output error no. if there are errors in operation of function block.
(g) If “Servo off” command is executed, corresponding servo driver will be “Servo off” state.
(a) Condition for servo of
(b) Axis ready state
(d) Command axis
(c) Position of the module
(e) Completion state
(f) Error state
Содержание XBF-PN04B
Страница 1: ...Programmable Logic Controller Positioning Module EtherCAT XGB Series XBF PN04B XBF PN08B ...
Страница 626: ...Chapter 9 Functions BPS37 setup RS232 and PC connection BPS37 option board LED 9 193 ...
Страница 628: ...Chapter 9 Functions c Execute BPS37 set up program and enter the setting values as follows 9 195 ...
Страница 796: ...Appendix3 Dimension A3 1 Appendix 3 Dimension Appendix 3 1 Dimension of XBF PN04B PN08B ...