Chapter 9 Functions
9-92
(3) Restrictions
(a) If there is no position/torque switching command input until the object gets to the target position, it slows
down and stops. Then positioning is complete.
(4) Setting example of operation data
Setting Items
Setting value
Description
Control method
Absolute, Single
axis position
control
When executing position/torque switching control, set single axis
position control
Operating
method
Single, End
Set operating method for position control
Target position
[pls]
10000
Set the value of target position for position control
Operating speed
[pls/s]
1000
Set the operating speed of position/torque switching control
Acc. no.
No.1
Set acc. no. used in acceleration (no.1~4)
Dec. no.
No.2
Set dec. no. used in deceleration (no.1~4)
M code
0
Set when you need to execute another auxiliary work based on the
position/torque switching control
Dwell time
500
Set dwell time(ms) needed to output the positioning completion signal
after positioning
Содержание XBF-PN04B
Страница 1: ...Programmable Logic Controller Positioning Module EtherCAT XGB Series XBF PN04B XBF PN08B ...
Страница 626: ...Chapter 9 Functions BPS37 setup RS232 and PC connection BPS37 option board LED 9 193 ...
Страница 628: ...Chapter 9 Functions c Execute BPS37 set up program and enter the setting values as follows 9 195 ...
Страница 796: ...Appendix3 Dimension A3 1 Appendix 3 Dimension Appendix 3 1 Dimension of XBF PN04B PN08B ...