Chapter 6 Command
6-81
6.3.53 Reset History Of Servo Error (Command: XSECLR)
(1) Program
(2) Description
Device
Description
M00039
Servo Error History Reset input
U02.00.0
Axis1 ready
D00000.0 Axis1 in operation
Comman
d
XSVOFF
Servo Disconnection
Operand
OP1 Slot
Constant
WOR
D
Slot No. installed with positioning module
OP2 Axis
PMLK,constant,D,Z,R,ZR
WOR
D
Command axis
XBF-PN04B: 1axis~4axis
XBF-PN08B:1axis~8axis
※
PMLK means P, M, L and K areas.
(a) This is the command that clears servo driver alarm history occurred at the specific axis among servo
drivers connected to the positioning module.
(b) Servo driver is saving up to 10 servo alarm history.
(c) You can see alarm history of the servo driver at the XG-PM. For further information, refer to XG-PM
manual.