Chapter 7 Function Block
7-14
7.4.2 Extended Parameter Teaching (XPM_SEP)
Form of Function Block
Description
Input
REQ : Request for execution of function block
BASE : Set the base no. with module
SLOT : Set the slot no. with module
AXIS : Axis to command
XBF-PN04B:1~4, XBF-PN08B:1~8
EP_VAL : Parameter value to modify
EP_NO : Item no. of parameter to modify
RAM/ROM : Method for saving parameter
0: Save at RAM
1: Save at ROM
Output
DONE : Maintain 1 after first operating
STAT : Output the error no. in operation
(1) Give “Extended Parameter Teaching” command to the axis designated as the axis of positioning module with
BASE (Base no. of Positioning module) and SLOT (Slot no. of Positioning module).
(2) Parameter value modified by extended parameter teaching command and setting RAM/ROM to “0” is valid
within power connection. If you want to keep the parameter without power connection, execute extended
parameter teaching command with setting RAM/ROM as “1” or save the modified parameter value on MRAM
with XPM_WRT (Parameter/Operation Data Saving command) after extended parameter teaching.
(3) You can set axis to command in “AXIS” and the following value is available. If you set other values, error code
“6” appears.
XBF-PN04B:1~4, XBF-PN08B:1~8
(4) Extended parameter setting command is unavailable to be executed when the axis is operating.
Содержание XBF-PN04B
Страница 1: ...Programmable Logic Controller Positioning Module EtherCAT XGB Series XBF PN04B XBF PN08B ...
Страница 626: ...Chapter 9 Functions BPS37 setup RS232 and PC connection BPS37 option board LED 9 193 ...
Страница 628: ...Chapter 9 Functions c Execute BPS37 set up program and enter the setting values as follows 9 195 ...
Страница 796: ...Appendix3 Dimension A3 1 Appendix 3 Dimension Appendix 3 1 Dimension of XBF PN04B PN08B ...