Chapter 8 Program
8-116
(i) Main Axis Setting
Set a main axis to operate Speed Synchronization. This setting is for main axis of Speed Synchronization.
This setting cannot be set as same value as Axis of command execution, and possible setting values are as
below.
(j) Value of Main Axis
Set value for Main Axis to execute Synchronous Start by Position. Therefore main axis will be executed the
command when the subordinate axis reaches this set value.
Set value
Main Axis
1
Axis1
2
Axis2
3
Axis3
4
Axis4
5
Axis5
6
Axis6
7
Axis7
8
Axis8
9
Encoder1
(k) State of Operation complete
If function block is completed without error, “1” will be outputted and m aintain “1” until the next operation. If
error occurred, “0” will be outputted.
(l) Error State
This is the area that output error no. if there are errors in operation of function block.
(m) For more information, reference for Synchronous Start by Position is in the “Chapter 9.4.2.”