1.
Put attachment on the ground, return all
control levers to the neutral position and
then set the pilot control shut-off lever to
the "LOCKED" position.
2.
Turn the starter switch to "OFF" for both
normal machine and disabled machine.
3.
Remove the terminal cover of the battery
and connect the jumper cable (red) clip to
the positive (+) terminal on the battery of
disabled machine.
4.
Connect the clip from the other end of the
positive (+) jumper cable (red) to the
positive (+) terminal on the battery of
normal machine.
5.
Connect the jumper cable (black) clip to the
negative (-) terminal on the battery of
normal machine.
6.
Finally, connect the clip from the other
end of the negative (-) jumper cable (black)
to the upper frame of disabled machine,
away from the battery.
7.
Start the engine of normal machine, and
run it for about 10 minutes at high idle.
8.
Start the engine of disabled machine.
9.
After starting the engine of disabled
machine, remove the jumper cables in the
reverse procedure of the connection.
10. Check and repair the cause of the
problem of the starting/charging system on
the disabled machine.
1
1.9.4
USING JUMPER CABLES TO START THE ENGINE
1. Use the same capacity battery of disabled battery for the boosting battery.
2. Connect the clip of jumper cables securely.
3. Check that the pilot control shut-off lever is in the "LOCKED" position.
4. Check that each control lever is returned to the neutral position.
5. Turn off the both starter switches of the normal machine and the disabled machine. When the
machine is powered on, the machines may unexpectedly start and it may cause an accident.
Procedure:
1.9.5
BATTERY DISPOSAL
Observe any local rules when disposing of a waste battery.
[
1. SAFETY PRECAUTIONS
]
1-43
Copyright © 2015 Kobelco Construction Machinery Co.,Ltd. All rights reserved. [S2PX00051ZE03] [0731CsCshWbYs]