1.
Put attachment on the ground, return all
control levers to the neutral position and
then set the pilot control shut-off lever to
the "LOCKED" position.
2.
Set the starter switch to the "OFF"
position for both the normal machine and
the disabled machine.
3.
Remove the terminal cover of the battery,
and connect the jumper cable (red) clip to
the positive (+) terminal on the battery of
the disabled machine.
4.
Connect the jumper cable (red) clip to the
positive (+) terminal on the battery of the
normal machine.
5.
Connect the jumper cable (black) clip to the
negative (-) terminal on the battery of the
normal machine.
6.
Finally, connect the jumper cable (black)
clip (-) to the engine body (hook, etc.) of
the disabled machine.
7.
Start the engine of the normal machine,
and run it for about 10 minutes at high
idle. The battery of the disabled machine
is partially charged.
8.
Start the engine of the disabled machine.
9.
Soon after the starting of the engine of
the disabled machine, remove the jumper
cables in the reverse procedure of the
connection.
10. Check and repair the cause of the
problem of the charging system on the
disabled machine.
3
3.4.4
CONNECTING/DISCONNECTING JUMPER CABLES
Turn the starter switch to the "OFF" position (engine stop) and connect the jumper cables according
to the procedure below.
CONNECTING/DISCONNECTING JUMPER CABLES
Wrong connection of jumper cables may cause explosion of the battery.
The starting system of this machine is 12 volts. Therefore the boost battery voltage in use should be
12 volts.
The application of high voltage employed for welding machine, etc. may cause damage to the electrical
system.
[
3. MACHINE OPERATION
]
3-15
Copyright © 2015 Kobelco Construction Machinery Co.,Ltd. All rights reserved. [S2PX00051ZE03] [0731CsCshWbYs]