Inspection and maintenance item
Greasing point
Replacement interval (hours)
First time
Second time
Periodic
Hydraulic oil
Hydraulic oil
tank
-
-
Every 1000
Return filter element kit
Hydraulic oil
tank
50
200
Every 200
7.4
PERIODIC INSPECTION AND MAINTENANCE OF NIBBLER
(CRUSHER) AND BREAKER
7.4.1
PERIODIC INSPECTION AND MAINTENANCE CHART OF NIBBLER
(CRUSHER) AND BREAKER
Contamination and deterioration of the hydraulic oil may cause poor function of the control valves,
early wear and seizure of the hydraulic pump and failure of the whole hydraulic circuit. When the
hydraulic breaker is attached, the deterioration of the hydraulic oil is faster than that of the normal
bucket digging work. Replace the filters and hydraulic oil earlier as indicated in the periodic inspection
and maintenance chart below.
[
7. NIBBLER (CRUSHER) AND BREAKER
]
7-12