181
13 Technical data
13
Technical data
13.1
General information
13.1.1
Reference conditions according to EN 29104
13.1.2
Maximum measurement deviation
JUMO flowTRANS MAG S01
JUMO flowTRANS MAG S02
JUMO flowTRANS MAG H01
JUMO flowTRANS MAG H02
Measuring medium temperature
20 °C (68 °F) ±2 K
Ambient temperature
20 °C (68 °F) ±2 K
Voltage supply
Nominal voltage according to the nameplate
V
n
±1 %, frequency f ±1 %
Installation conditions
Supply side > 10 x DN pipe section
Return side > 5 x DN pipe section
Warm-up phase
30 min
IMPORTANT (NOTE)!
Q
max
DN
See table chapter 7.6 "Nominal width, measuring range", page 92.
Calibration (pulse output)
Nominal width
±0.4% of the measured value, ±0.02% QmaxDN
(standard)
DN 3 to 2,000
±0.2% of measured value, ±0.02% QmaxDN (option-
al)
DN 10 to 600, 800
Calibration (pulse output)
Nominal width
±0.3% of the measured value, ±0.02% QmaxDN
(standard)
DN 3 to 600, 800
±0.4% of the measured value, ±0.02% QmaxDN
(standard)
DN 700, 900 to 2,000
±0.2% of measured value, ±0.02% QmaxDN (option-
al)
DN 10 to 600, 800
Calibration (pulse output)
Nominal width
±0.4% of the measured value, ±0.02% QmaxDN
(standard)
DN 3 to 100
±0.2% of measured value, ±0.02% QmaxDN (option-
al)
DN 10 to 100
Calibration (pulse output)
Nominal width
±0.3% of the measured value, ±0.02% QmaxDN
(standard)
DN 3 to 100
±0.7% of the measured value, ±0.02% QmaxDN
(standard)
DN 1 to 2
Содержание flowTRANS MAG H01
Страница 2: ......
Страница 22: ...1 Safety 22...
Страница 68: ...5 Electrical connection 68...
Страница 72: ...6 Digital communication 72...
Страница 94: ...7 Startup 94...
Страница 108: ...8 Parameterization 108...
Страница 109: ...109 8 Parameterization...
Страница 110: ...8 Parameterization 110...
Страница 111: ...111 8 Parameterization...
Страница 112: ...8 Parameterization 112...
Страница 152: ...8 Parameterization 152...
Страница 160: ...9 Advanced diagnostics functions 160...
Страница 258: ...14 Annex 258...
Страница 259: ......