49
4 Mounting
4.5.3
Metal pipe with loose flanges
Using the example of the dual-compartment transmitter housing
1. Weld the threaded bolts M6 (1) to the pipeline and establish the ground connection as shown in the
illustration.
2. Establish the connection between the ground terminal (2) of the sensor and a suitable grounding
point using a copper wire [at least 2.5 mm
2
(14 AWG)] according to the figure.
4.5.4
Sensor model 406015 and 406016
Using the example of the dual-compartment transmitter housing
The grounding is established as displayed in the figure. The measurement medium is grounded via the
adapter (1) so that an additional grounding is not required.
An additional grounding is only required for the "wafer" process connection
See figures
chapter 4.5.2 "Metal pipe with fixed flanges", page 48 and chapter 4.5.3 "Metal pipe with loose flanges",
page 49.
Flange version
Model 406012, 406013, 406015 and 406016
Connection flange design
Model 406015 and 406016
(1)
Threaded bolts
(2)
Ground terminal
(1)
(2)
(1)
(2)
(1)
Adapter
(1)
Содержание flowTRANS MAG H01
Страница 2: ......
Страница 22: ...1 Safety 22...
Страница 68: ...5 Electrical connection 68...
Страница 72: ...6 Digital communication 72...
Страница 94: ...7 Startup 94...
Страница 108: ...8 Parameterization 108...
Страница 109: ...109 8 Parameterization...
Страница 110: ...8 Parameterization 110...
Страница 111: ...111 8 Parameterization...
Страница 112: ...8 Parameterization 112...
Страница 152: ...8 Parameterization 152...
Страница 160: ...9 Advanced diagnostics functions 160...
Страница 258: ...14 Annex 258...
Страница 259: ......