147
8 Parameterization
8.5
Alarm Simulation
Different alarms can be simulated in the "Process alarm/alarm simulation" menu.
Menu/Parameter
Description
Process alarm/
Alarm simulation
Off
Alarm simulation switched off
0-Sim.CurrentOut
Simulate current output
1-Sim.Logic on DO1
Switch on/off switching output (terminal 51/52)
2-Sim.Pulse on DO1
Simulate pulse output (terminal 51/52)
3-Sim.Logic on DO2
Switch on/off switching output (terminal 41/42)
4-Sim.Pulse on DO2
Simulate pulse output (terminal 51/52)
5-Min Alarm Flowrate
Simulate min. flow alarm
6-Max Alarm Flowrate
Simulate max. flow alarm
7-Flowrate >103%
Simulate flow > 103 % as an alarm
8-Flow Simulation
Simulate flow simulation
9-Calibration Mode
Simulate transmitter alarm at the simulator
10-Flowrate to Zero
Simulate flowrate to zero
11-Totalizer Stop
Simulate external totalizer stop
12-Tot.Display<1600h
Simulate display value < 1600 h at Q
max
13-Totalizer Reset
Simulate Totalizer Reset
14-Err.Sensor-Comms
Simulate distorted communication to the SensorMemory
15-HART Address <> 0
Simulate HART Multiplex mode
16-FRAM-Com Fail
17-No Sensor
Simulate "No communication to SensorMemory" error
18-Sim.Digital Input
Simulation of the "ON/OFF" digital input
19-ADC saturated
Simulate "AD converter override" error
20-Error Coil circ
Simulate error in the coil circuit
21-Coil Resistor
Simulate "Coil resistance out of limits" error
22-Driver Err Uref=0
Simulate "Reference voltage = 0" error
23-El.Noise too High
Simulate "Noise signal too high" error
24-DC to High
Simulate "DC too high, several NV resets" error
25-Empty Pipe
Simulate "Empty pipe" error
27-NV Corrupt
Simulate "NV Corrupt" error
29-Electrode Imp.
Simulate "Electrode impedance out of limits" error
30-Hold Last Value
Simulate "Hold last good value" error
32-Digi-Pot Error
Simulate "Digital potentiometer" error
33-TFE
Simulate "Partial filling alarm" error
34-CurrentOut Error
Simulate "Loop current output interrupted" error
35-Not Calibrated
Simulate "Not calibrated" error
36-SensorIncompatib.
Simulate "Incompatible Sensor" error
37-ROM Error
Simulate ROM error in the transmitter
38-RAM Error
Simulate RAM error in the transmitter
39-Sim. HART Freq.
Simulation of a HART frequency
40-SIL
Simulate "Self check alarm" error
41-Conductivity
Simulate "Conductivity alarm" error
42-Elec.Coated
Simulate "Electrode deposits" error
Содержание flowTRANS MAG H01
Страница 2: ......
Страница 22: ...1 Safety 22...
Страница 68: ...5 Electrical connection 68...
Страница 72: ...6 Digital communication 72...
Страница 94: ...7 Startup 94...
Страница 108: ...8 Parameterization 108...
Страница 109: ...109 8 Parameterization...
Страница 110: ...8 Parameterization 110...
Страница 111: ...111 8 Parameterization...
Страница 112: ...8 Parameterization 112...
Страница 152: ...8 Parameterization 152...
Страница 160: ...9 Advanced diagnostics functions 160...
Страница 258: ...14 Annex 258...
Страница 259: ......