7 Startup
92
7.6
Nominal width, measuring range
The measuring range end value can be configured between 0.02xQ
max
DN and 2xQ
max
DN.
Nominal width
Minimum
Measuring range end value
0.02xQ
max
DN (≈ 0.2 m/s)
Q
max
DN
0 to ≈ 10 m/s
Maximum
Measuring range end value
2xQ
max
DN (≈ 20 m/s)
DN (inch)
l/min
US gal/min
l/min
US gal/min
l/min
US gal/min
1 (1/25)
0.012
0.0032
0.6
0.16
1.2
0.32
1.5 (1/16)
0.024
0.0063
1.2
0.32
2.4
0.63
2 (1/12)
0.04
0.0106
2
0.53
4
1.06
3 (1/10)
0.08
0.02
4
1.06
8 l/min
2.11
4 (5/32)
0.16
0.04
8
2.11
16 l/min
4.23
6 (1/4)
0.4
0.11
20
5.28
40
10.57
8 (5/16)
0.6
0.16
30
7.93
60
15.85
10 (3/8)
0.9
0.24
45
11.9
90
23.78
15 (1/2)
2
0.53
100
26.4
200
52.8
20 (3/4)
3
0.79
150
39.6
300
79.3
25 (1)
4
1.06
200
52.8
400
106
32 (1 1/4)
8
2.11
400
106
800
211
40 (1 1/2)
12
3.17
600
159
1200
317
Nominal width
Minimum
Measuring range end value
0.02xQ
max
DN (≈ 0.2 m/s)
Q
max
DN
0 to ≈ 10 m/s
Maximum
Measuring range end value
2xQ
max
DN (≈ 20 m/s)
DN (inch)
m
3
/h
US gal/min
m
3
/h
US gal/min
m
3
/h
US gal/min
50 (2)
1.2
5.28
60
264
120
528
65 (2 1/2)
2.4
10.57
120
528
240
1057
80 (3)
3.6
15.9
180
793
360
1585
100 (4)
4.8
21.1
240
1057
480
2113
125 (5)
8.4
37
420
1849
840
3698
150 (6)
12
52.8
600
2642
1200
5283
200 (8)
21.6
95.1
1080
4755
2160
9510
250 (10)
36
159
1800
7925
3600
15850
300 (12)
48
211
2400
10567
4800
21134
350 (14)
66
291
3300
14529
6600
29059
400 (16)
90
396
4500
19813
9000
39626
450 (18)
120
528
6000
26417
12000
52834
500 (20)
132
581
6600
29059
13200
58117
600 (24)
192
845
9600
42268
19200
84535
700 (28)
264
1162
13200
58118
26400
116236
760 (30)
312
1374
15600
68685
31200
137369
800 (32)
360
1585
18000
79252
36000
158503
900 (36)
480
2113
24000
105669
48000
211337
1000 (40)
540
2378
27000
118877
54000
237754
1050 (42)
616
2712
30800
135608
61600
271217
1100 (44)
660
3038
33000
151889
66000
290589
1200 (48)
840
3698
42000
184920
84000
369841
Содержание flowTRANS MAG H01
Страница 2: ......
Страница 22: ...1 Safety 22...
Страница 68: ...5 Electrical connection 68...
Страница 72: ...6 Digital communication 72...
Страница 94: ...7 Startup 94...
Страница 108: ...8 Parameterization 108...
Страница 109: ...109 8 Parameterization...
Страница 110: ...8 Parameterization 110...
Страница 111: ...111 8 Parameterization...
Страница 112: ...8 Parameterization 112...
Страница 152: ...8 Parameterization 152...
Страница 160: ...9 Advanced diagnostics functions 160...
Страница 258: ...14 Annex 258...
Страница 259: ......