169
10 Error messages
C172.04
Configuration
Pulse Simulation selected
on DO2
Current value
No response
Simulated
value
Current
value
Mask group
Switch off Simulation Mode
C168.01
Configuration
Logic Simulation selected
on DO1
Current value
Simulated val-
ue
No re-
sponse
Current
value
Mask group
Switch off Simulation Mode
C164.03
Configuration
Logic Simulation selected
on DO2
Current value
Simulated val-
ue
No re-
sponse
Current
value
Mask group
Switch off Simulation Mode
C158.039
Configuration
Simulation of HART fre-
quency
Current value
No response
Current
value
Current
value
Mask group
Switch off Simulation Mode
C154.018
Configuration
Simulation Digital In
Current value
No response
Current
value
Current
value
Mask group
Switch off Simulation Mode
C149.021
Sensor
Coil resistor out of limits
Current value
No response
Current
value
Current
value
Mask group
Check wiring
Contact service
S148.025
Operation
Empty Pipe
Programmed
alarm
Programmed
alarm
0 Hz
0 %
Mask single
alarm
Check Pipe
S149.021
Operation
Coil resistor out of limits
No response
No response
No re-
sponse
No re-
sponse
Mask group
Check wiring
Contact service
S146.043
Operation
Gas Bubble Alarm
Current value
Programmed
alarm
Current
value
Current
value
Mask group
S144.033
Operation
Partially filled pipe (TFE)
Programmed
alarm
Programmed
alarm
Current
value
Current
value
Mask group
Check pipe or adjust Detec-
tor
S143.042
Operation
Electrode Coating Alarm
Current value
Programmed
alarm
Current
value
Current
value
Mask group
S142.041
Operation
Conductivity Alarm
Current value
Programmed
alarm
Current
value
Current
value
Mask group
S141.046
Operation
Sensor and or Housing
Temperature to high
Current value
Programmed
alarm
Current
value
Current
value
Mask group
S140.007
Operation
Flowrate > 103 %
Programmed
alarm
Collective
alarm
Current
value
Current
value
Mask single
alarm
Check Flowrate
Check Range Setting
S136.006
Operation
Max Alarm
Flowrate
Current value
Programmed
alarm
Current
value
Current
value
Mask single
alarm
S132.05
Operation
Min Alarm
Flowrate
Current value
Programmed
alarm
Current
value
Current
value
Mask single
alarm
S124.029
Operation
Electr. Impedance too high Current value
No response
Current
value
Current
value
Mask group
Coating?
Conductivity?
Empty Pipe?
S122.026
Operation
Short circuit E1
Current value
No response
Current
value
Current
value
Mask group
E2 with shield
Error no./
area
Text in the
LCD display
Current
output
behavior
Digital
output
behavior
Pulse
output
behavior
Display
Error
can be
masked?
Содержание flowTRANS MAG H01
Страница 2: ......
Страница 22: ...1 Safety 22...
Страница 68: ...5 Electrical connection 68...
Страница 72: ...6 Digital communication 72...
Страница 94: ...7 Startup 94...
Страница 108: ...8 Parameterization 108...
Страница 109: ...109 8 Parameterization...
Страница 110: ...8 Parameterization 110...
Страница 111: ...111 8 Parameterization...
Страница 112: ...8 Parameterization 112...
Страница 152: ...8 Parameterization 152...
Страница 160: ...9 Advanced diagnostics functions 160...
Страница 258: ...14 Annex 258...
Страница 259: ......