3 Transport and storage
32
3.2.2
Flange devices greater than DN 400
When transporting flange devices with a nominal width greater than DN 400, always use the lifting eyes
attached to the device for lifting and depositing the device in the pipeline.
3.3
Storage
When storing the device, the following points must observed:
•
Store the device in the original packaging at a dry and dust-free location
•
Avoid continuous direct sunlight
3.3.1
Nominal widths greater than DN 400
Devices with a nominal width greater than DN 400 must be set up on a foundation with a sufficient load-
bearing capacity using a support.
WARNING – Risk of injury!
Do not lift flange devices directly on the connection box or housing centre!
CAUTION – Device damage!
•
Do not use chains to lift the flange devices!
•
Avoid transporting with a forklift!
During transport with a forklift, the housing and the magnetic coils on the inside can be damaged
see
also chapter 3.3.1 "Nominal widths greater than DN 400", page 32.
CAUTION – Device damage!
If not supported correctly, the housing and the magnetic coils on the inside can be damaged. Apply the
supports to the edge of the housing (see arrows in figure).
Содержание flowTRANS MAG H01
Страница 2: ......
Страница 22: ...1 Safety 22...
Страница 68: ...5 Electrical connection 68...
Страница 72: ...6 Digital communication 72...
Страница 94: ...7 Startup 94...
Страница 108: ...8 Parameterization 108...
Страница 109: ...109 8 Parameterization...
Страница 110: ...8 Parameterization 110...
Страница 111: ...111 8 Parameterization...
Страница 112: ...8 Parameterization 112...
Страница 152: ...8 Parameterization 152...
Страница 160: ...9 Advanced diagnostics functions 160...
Страница 258: ...14 Annex 258...
Страница 259: ......