HV100 Series High Performance Current Vector Inverter
15
4.2.2 The terminal for controlling loop
Function description of control circuit terminal
Classifica
tion
Terminal
label
Description of functions
Specification
Multifuncti
onal digital
input
terminal
DI1
Short circuit between DI(DI1, DI2, DI3, DI4, DI5,
DI6, HDI) ~ COM is valid, and its functions are
set by parameters 07.00 ~ 07.06 respectively
(common terminal: com).
Input, 0 ~ 24V level signal, active at
low level, 5mA.
DI2
DI3
DI4
DI5
DI6
DI7(HDI)
HDI can be used as a common multi-function
terminal, and can also be programmed as a
high-speed pulse input port. see 07.06
functional description for details.
Analog
input and
output
terminals
AI1
AI1 receives analog voltage/current input. The
voltage and current are selected by jumper JP3.
The factory default input voltage. If the current
is to be input, just adjust the jumper cap to
Cin
position. AI2 only receives voltage input. See
the description of function code 06.01 ~ 06.10
for the setting of measuring range. (reference
ground: GND)
INPUT, input voltage range: 0 ~ 10v
(input impedance: 100KΩ), input
current range: 0 ~ 20ma (input
impedance: 500Ω).
AI2
AO1
AO1 provides analog voltage/current output,
which can represent 14 physical quantities.
The output voltage and current are selected by
jumper JP4, and the factory default output
voltage. If you want to output current, just jump
the jumper cap to Co1 position. See description
of function codes 06.21 and 06.22 for details.
(reference ground: GND)
OUTPUT, 0 ~ 10v DC voltage.
Output voltages of AO1 and AO2
terminals are PWM waveforms
from the central processing unit.
The output voltage is proportional
to the width of PWM waveform.
AO2
(Reserved)
Relay
output
terminal
TA1
Programmable relay output terminals are
defined as multi-functions, with 62 types. See
07.20 and 07.21 for details.
TA1-TB1 and TA2-TB2 are
normally closed;
TA1-TC1 and TA2-TC2 are
normally open.
Contact capacity: 250vac/2a (cos ф
= 1);
250VAC/1A(COSФ=0.4),30VDC/1
A.
TB1
TC1
TA2
TB2
TC2
Open
Collector
output
terminal
HDO
Programmable defined as multifunctional
collector output terminals, up to 62 kinds. See
07.18 and 07.19 for details.
1. Switching capacity: 50mA/30V
2. Output frequency range:
0~50kHz
Y1
1. Switching capacity: 50mA/30V
2. Output frequency range: 0~1kHz