HV100 Series High Performance Current Vector Inverter
136
01H is the inverter address
13H is the write function code
08H is the total number of bytes (number of 2* registers)
1388H is the parameter value
0322H is the attribute value
0000H is the minimum value
1388H is the maximum value
2831H is a 16-bit CRC check code
Example:
Name
Frame lattice
Read the parameter value
of item 00.12
Send frame: 01H 13H 000CH 001H 85CAH
Return frame: 01H 13H 02H 1388H B1D2H
Read the parameter value
of item 00.12 + the
attribute value
Send frame: 01H 13H 000CH 0002H C5CBH
Return frame
:
01H 13H 04H 1388H 0322H FC00H
Read
the
parameter
value+attribute
value+minimum value of
item 00.13
Send frame: 01H 13H 000CH 0003H 040BH
Return frame
:
01H 13H 06H 1388H 0322H 0000H 628BH
Read
the
parameter
value+attribute
value+minimum
value+maximum value of
item 00.13
Send frame: 01H 13H 000CH 0004H 45CBH
Return frame
:
01H 13H 08H 1388H 0322H 0000H 1388H 2831H
3. Description of other register address functions:
Functional
Description
address
definition
Explanation of data meaning
Inverter
running
state
A000H(1A00H)
bytes
bit
Meaning
Byte1
Bit7
0: no-operation
1: Overload warning
Bit6
~
Bit5
0:INV_220V
1:INV_380V
2:INV_660V
3:INV_1140V
Bit4
0: no-operation
1: power-down storage
Bit3
0:no-operation
1:Reset
Bit2
~
Bit1
0: no-operation
1. Static tuning
2. Dynamic tuning
Bit0
0: the keypad runs the command
channel
1: terminal operation command channel
2: Communication operation command
channel
3: Reservation
Byte0
Bit7
Inverter
running
state
Bit6
0: no-operation
1: the bus voltage is normal
Bit5
0: no-operation
1. Undervoltage
Bit4
0: no-operation
1: JOG
Bit3
0: forward
1: reverse