HV100 Series High Performance Current Vector Inverter
123
14.11
Parameter display mode selection
00
~
1011
0100
LED bits: Function parameter display mode selection
0: Display all function parameters
1: Only parameters different from the factory values are displayed
2: Only display the parameters modified after the last power-on (reserved)
LED ten bits: Monitor parameter display mode selection
0: Only the main monitoring parameters are displayed
1: Main and auxiliary display alternately (interval is 1S)
LED hundred bits: Reserved
LED thousand bits: Panel ▲/▼ key adjustment enable
0: Valid
1: Invalid
14.12
Parameter initialization
0
~
3
0
0: No-operation
The inverter is in normal parameter reading and writing status. Whether the function code setting value can be
changed is related to the setting status of the user password and the current operating status of the inverter.
1: All user parameters except motor parameters are restored to factory settings
The motor parameters are not restored, and other user parameters are restored to the factory set values according to
the model.
2: All user parameters are restored to factory settings
All user parameters are restored to the factory settings according to the model.
3: Clear fault record
Clear the contents of fault records (D-48 ~ D-57).
After the operation is completed, this function code is automatically cleared to 0 .
14.13
Parameter protection
0
~
2
0
0: All parameters are allowed to be modified (some parameters cannot be modified during operation)
1: Only the frequency setting parameters 00.09 , 00.10 and this function code can be modified
2: All parameters except this function code are forbidden to be modified
14.14
Parameter copy function
0
~
3
0
0: No operation
1: Upload parameters to the panel
After setting it to 1, and confirming, the panel displays CP-1, and the inverter uploads all the function code parameters
in the control panel to the EEPROM of the operation panel for storage.
2: All function code parameters are downloaded to the inverter
After setting it to 2 and confirming it, the panel displays CP-2, and the inverter downloads all the function code
parameters in the operation panel except the manufacturer parameters to the memory of the main control board, and
refreshes the EEPROM.
3: All function code parameters except the motor parameters are downloaded to the inverter
After setting it to 3 and confirming it, the panel displays CP-3, the inverter downloads all the function code parameters
in the operation panel to the main control board memory (except the motor parameter group and the manufacturer
parameter group), and refreshes the EEPROM.
14.15
Software version
1.00
~
99.99
4.12
14.16
Keypad version
1.00
~
99.99
1.00
14.17
Inverter rated power
0.4
~
999.9KW
(
G/P
)
Model setting