HV100 Series High Performance Current Vector Inverter
56
Function
code
Name
Content
Setting
range
Factory
Alteration
16.00
Lack
of
water
detect time
If the bus voltage (d-12) is higher than the set value of
MPPT high working voltage (16.02), it will run at the
maximum frequency; if it is lower than the set value of
MPPT high working voltage (16.01), it will be operated
according to (bus voltage/MPPT high point operating
voltage) * Maximum frequency operation. If the bus
voltage reaches the MPPT low point operating voltage
(16.01), it will run at the lowest water output frequency
(16.04). If the inverter runs above the lowest water
frequency and the output current is less than Motor
no-load current * Photovoltaic water pump water
shortage detection current corresponds to the ratio of
no-load current (16.03). After the photovoltaic water
pump water shortage detection time (16.00), the inverter
reports water shortage fault E-32.
0
~
250s
10
○
16.01
MPPT low point
operating Voltage
0
~
MPPT
High
operating
voltage
350/200V
○
16.02
MPPT high point
operating Voltage
【
16.01
】~
1000 /
【
16.01
】~
500
537/311V
○
16.03
Photovoltaic pump
water
shortage
detection current
corresponds to the
ratio of no-load
current
80.0
~
300.0%*
High
operating
voltage
150.0
○
16.04
Minimum
operating
frequency of
photovoltaic water
pump
0.00Hz
~
Upper limit
frequency
20.00
○
d-xx Group-Monitoring parameter group and fault record
Function
code
Name
Setting range
Factory
Alteratio
n
d-00
Output frequency
0.00
~
Max output frequency
【
00.13
】
0
◆
d-01
Settings frequency
0.00
~
Max output frequency
【
00.13
】
0
◆
d-02
Motor estimated frequency
0.00
~
Max output frequency
【
00.13
】
Note: the running
frequency of the motor is calculated from the
estimated speed of the motor
0
◆
d-03
Main frequency
0.00
~
Max output frequency
【
00.13
】
0
◆
d-04
Auxiliary frequency
0.00
~
Max output frequency
【
00.13
】
0
◆
d-05
Output current
0.0
~
6553.5A
0
◆
d-06
Output voltage
0
~
999V
0
◆
d-07
Output Torque
-200.0
~
+200.0%
0
◆
d-08
Motor rotation speed(rpm)
0
~
36000
(
rpm
)
0
◆
d-09
Motor power factor
0.00
~
1.00
0
◆
d-10
Running line speed(m/s)
0.01
~
655.35(m/s)
0
◆
d-11
Setting line speed(m/s)
0.01
~
655.35(m/s)
0
◆
d-12
DC bus voltage(V)
0
~
999V
0
◆
d-13
Input voltage(V)
0
~
999V
0
◆
d-14
PID setting value(V)
0.00
~
10.00V
0
◆
d-15
PID feedback value(V)
0.00
~
10.00V
0
◆
d-16
Analog input AI1(V/mA)
0.00
~
10.00V
0
◆
d-17
Analog input AI2(V)
0.00
~
10.00V
0
◆
d-18
Pulse frequency input (KHz)
0.00
~
50.00kHz
0
◆
d-19
Analog output AO1(V/mA)
0.00
~
10.00V
0
◆
d-20
Analog output AO2(V)
0.00
~
10.00V
0
◆
d-21
Input terminal status
0 ~ 7fh Note: After expanding to binary, it means
HDI/DI6/DI5/DI4/DI3/DI2/DI1 from high to low
0
◆
d-22
Output terminal status
0 ~ FH Note: After expanding to binary, it means
R2/R1/Y2/Y1 from high to low
0
◆
d-23
Operation
status
of
frequency
converter
0
~
FFFFH
BIT0: Start/Stop
BIT1: Forward/Reverse
BIT2: Zero speed operation
BIT3: Reserved
BIT4: Acceleration
BIT5: Deceleration
BIT6: Constant speed
BIT7: Pre-excitation
BIT8: Motor parameter tuning
BIT9: Over current limiting
BIT10: Over voltage limiting
0
◆