HV100 Series High Performance Current Vector Inverter
104
09.04
Finite number of continuous cycles
1
~
65535
1
09.05
Selection of PLC running time unit
0
~
1
0
0
:
s
1
:
min
09.06
Multi speed frequency 0
-upper limit frequency ~ upper limit frequency
5.00
09.07
Multi speed frequency 1
-upper limit frequency ~ upper limit frequency
10.00
09.08
Multi speed frequency 2
-upper limit frequency ~ upper limit frequency
15.00
09.09
Multi speed frequency 3
-upper limit frequency ~ upper limit frequency
20.00
09.10
Multi speed frequency 4
-upper limit frequency ~ upper limit frequency
25.00
09.11
Multi speed frequency 5
-upper limit frequency ~ upper limit frequency
30.00
09.12
Multi speed frequency 6
-upper limit frequency ~ upper limit frequency
40.00
09.13
Multi speed frequency 7
-upper limit frequency ~ upper limit frequency
50.00
09.14
Multi speed frequency 8
-upper limit frequency ~ upper limit frequency
0.00
09.15
Multi speed frequency 9
-upper limit frequency ~ upper limit frequency
0.00
09.16
Multi speed frequency 10
-upper limit frequency ~ upper limit frequency
0.00
09.17
Multi speed frequency 11
-upper limit frequency ~ upper limit frequency
0.00
09.18
Multi speed frequency 12
-upper limit frequency ~ upper limit frequency
0.00
09.19
Multi speed frequency 13
-upper limit frequency ~ upper limit frequency
0.00
09.20
Multi speed frequency 14
-upper limit frequency ~ upper limit frequency
0.00
09.21
Multi speed frequency 15
-upper limit frequency ~ upper limit frequency
0.00
The sign of multi-speed determines the direction of operation, and negative indicates the opposite direction of
operation. The frequency input mode is set by 00.07=6, and the start-stop command is set by 00.06.
09.22
0 speed acceleration and deceleration time
0
~
3
0
09.23
0 speed running time
0.0~6553.5S(M
)
0.0
09.24
1st speed acceleration and deceleration time