HV100 Series High Performance Current Vector Inverter
133
Starting data address
20H
00H
Data(2Byte)
00H
01H
CRC CHK Low
43H
CRC CHK High
CAH
Analysis of this data:
01H is the inverter address
06H is the write function code
2000H is the control command address
001H is the forward command
43CAH is a 16-bit CRC validation code
The Response information frame format (return frame)
Address
01H
Function
06H
Starting data address
20H
00H
Number of Data(Byte)
00H
01H
CRC CHK High
43H
CRC CHK Low
CAH
Analysis of this data: If the settings are correct, return the same input data
Example:
Name
Frame lattice
Forward
Send frame: 01H 06H 2000H 001H 43CAH
Return frame: 01H 06H 2000H 001H 43CAH
Reverse rotation
Send frame: 01H 06H 2000H 0009H 420CH
Return frame: 01H 06H 2000H 0009H 420CH
Shutdown
Send frame: 01H 06H 2000H 0003H C20BH
Return frame: 01H 06H 2000H 0003H C20BH
free stop
Send frame: 01H 06H 2000H 0004H 83C9H
Return frame: 01H 06H 2000H 0004H 83C9H
Reset
Send frame: 01H 06H 2000H 010H 43CAH
Return frame: 01H 06H 2000H 010H 43CAH
Forward JOG
Send frame: 01H 06H 2000H 0002H 03CBH
Return frame: 01H 06H 2000H 0002H 03CBH
Reverse JOG
Send frame: 01H 06H 2000H 000AH 020DH
Return frame: 01H 06H 2000H 000AH 020DH
Set the parameter of item 08.00 to 1
Send frame: 01H 06H 0800H 001H 4A6AH
Return frame: 01H 06H 0800H 001H 4A6AH
MODBUS the given frequency is 40HZ
Send frame: 01H 06H 201H 0FA0H D642H
Return frame: 01H 06H 201H 0FA0H D642H
The MODBUS PID given value is 5V
Send frame: 01H 06H 2003H 01F4H 721DH
Return frame: 01H 06H 2003H 01F4H 721DH
The feedback value of MODBUS PID is 4V
Send frame: 01H 06H 2004H 0190H C237H
Return frame: 01H 06H 2004H 0190H C237H
MODBUS the torque is set as 80
:
Send frame: 01H 06H 2002H 0320H 22E2H