GREE GMV5 HR HEAT RECOVERY UNITS
26
Outdoor Units_Heat Recovery
Ton
28
30
Model
-
GMV-Q336WM/B-U(U)
GMV-Q360WM/B-U(U)
Module combination
-
GMV-Q96WM/B-U(U)
+GMV-Q120WM/B-U(U)
+GMV-Q120WM/B-U(U)
GMV-Q120WM/B-U(U)
+GMV-Q120WM/B-U(U)
+GMV-Q120WM/B-U(U)
Cooling Power Input
kW
7.30+9.58+9.58
9.58+9.58+9.58
Heating Power Input
kW
7.85+10.42+10.42
10.42+10.42+10.42
Sound Pressure
Level
dB(A)
-
-
Power Supply
-
460V 3~ 60Hz
Compressor
Type
-
Inverter scroll type
Inverter scroll type
Number
N
1+2+2
2+2+2
Motor Output
①
kW
-
-
Starting Method
-
Inverter
Inverter
Operating Range
-
-
-
Refrigeration Oil
Brand
-
FVC68D or FV-68H
FVC68D or FV-68H
Fan
Type×Quantity
-
Propeller×(2+2+2)
Propeller×(2+2+2)
Motor output
W
750×2+750×2+750×2
750×2+750×2+750×2
Starting method
-
Inverter
Inverter
Air flow rate
m
3
/h
14000+14000+14000
14000+14000+14000
cfm
8240+8240+8240
8240+8240+8240
Max. external static
pressure
Pa
82
82
in.W.G
0.328
0.328
Ambient
temperature
range
Cooling
°C
-5~52
-5~52
°F
23~125.6
23~125.6
Heating
°C
-20~24
-20~24
°F
-4~75.2
-4~75.2
Refrigerant
Refrigerant Type
-
R410A
R410A
Refrigerant Charge
Volume
kg
11.2+11.7+11.7
11.7+11.7+11.7
lbs.
25+25.79+25.79
25.79+25.79+25.79
Control
-
EXV
EXV
Pipe
Connection
Low pressure Gas
Pipe Size
mm
34.9
41.3
in.
1 3/8
1 5/8
high pressure gas
pipe
mm
28.6
34.9
in.
1 1/8
1 3/8
Liquid Pipe Size
mm
19.05
19.05
in.
3/4
3/4
Dimensions
(width×depth
×height)
External Dimension
mm
1340×765×1605+1340×765×1605
+1340×765×1605
1340×765×1605+1340×765×1605
+1340×765×1605
in.
52-3/4×30-1/8×63-1/5+52-3/4×30
-1/8×63-1/5+52-3/4×30-1/8×63-1/5
52-3/4×30-1/8×63-1/5+52-3/4×30
-1/8×63-1/5+52-3/4×30-1/8×63-1/5
Packaging
Dimension
mm
1420×840×1775+1420×840×1775
+1420×840×1775
1420×840×1775+1420×840×1775
+1420×840×1775
in.
55-7/8×33-1/8×69-7/8+55-7/8×33
-1/8×69-7/8+55-7/8×33-1/8×69-7/8
55-7/8×33-1/8×69-7/8+55-7/8×33
-1/8×69-7/8+55-7/8×33-1/8×69-7/8
Weight
Net Weight
kg
315+370+370
370+370+370
lbs.
684+816+816
816+816+816
Gross Weight
kg
330+385+385
385+385+385
lbs.
728+849+849
849+849+849
Maximum qty of connected indoor
units
unit
56
59
Содержание GC201808-III
Страница 36: ...GREE GMV5 HR HEAT RECOVERY UNITS 32 Circuit diagram of GMV Q144WM B1 F U Circuit diagram of GMV Q168WM B1 F U ...
Страница 87: ...GREE GMV5 HR HEAT RECOVERY UNITS 83 1 External Connection for Individual Units ...
Страница 92: ...GREE GMV5 HR HEAT RECOVERY UNITS 88 ...
Страница 227: ...GREE GMV5 HR HEAT RECOVERY UNITS 223 Troubleshooting ...
Страница 286: ...GREE GMV5 HR HEAT RECOVERY UNITS 282 Troubleshooting ...
Страница 314: ...GREE GMV5 HR HEAT RECOVERY UNITS 310 4 Loosen the screws on the compressor drive as shown in the figure below ...
Страница 362: ...JF00302879 ...