GREE GMV5 HR HEAT RECOVERY UNITS
15
Outdoor Units_Heat Recovery
Ton
12
14
16
Model
-
GMV-Q144WM/B-F(U) GMV-Q168WM/B-F(U) GMV-Q192WM/B-F(U)
Module combination
-
GMV-Q72WM/B-F(U)
+ GMV-Q72WM/B-F(U)
GMV-Q72WM/B-F(U)
+GMV-Q96WM/B-F(U)
GMV-Q96WM/B-F(U)
+GMV-Q96WM/B-F(U)
in.
55-7/8×33-1/8×69-7/8
+55-7/8×33-1/8×69-7/8
55-7/8×33-1/8×69-7/8
+55-7/8×33-1/8×69-7/8
55-7/8×33-1/8×69-7/8
+55-7/8×33-1/8×69-7/8
Weight
Net Weight
kg
302+302
302+310
310+310
lbs.
666+666
666+683
683+683
Gross Weight
kg
317+317
317+325
325+325
lbs.
699+699
699+716
716+716
Maximum qty of connected indoor
units
unit
23
29
33
Protection
Devices
High Pressure
Protection
High pressure sensor, High pressure switch
Compressor /Fan
Over-current protection, Over-heat protection
Inverter
Over-current protection, Over-heat protection, High/Low voltage protection,
Remark
It refers to the operation power of compressor under ARI test conditions (Condensing temp. 130°F;
Evaporating temp.45°F; Return gas temp.65°F; Liquid temp.115°F) at 60Hz.
Oil charge includes the total oil amount of outdoor units, residual oil amount of compressor and oil
separate tank. When replacing the compressor or oil separate tank, only the corresponding required oil
amount shall be charged.
Outdoor Units_Heat Recovery
Ton
18
20
22
Model
-
GMV-Q216WM/B-F(U)
GMV-Q240WM/B-F(U) GMV-Q264WM/B-F(U)
Module combination
-
GMV-Q96WM/B-F(U)
+GMV-Q120WM/B-F(U)
GMV-Q120WM/B-F(U)
+GMV-Q120WM/B-F(U)
GMV-Q72WM/B-F(U)
+GMV-Q96WM/B-F(U)
+GMV-Q96WM/B-F(U)
Performance
Nominal Cooling
Capacity
Btu/h
216000
240000
264000
kW
63.3
70.3
77.4
Rated Cooling
Capacity
Btu/h
201000
222000
247000
Nominal Heating
Capacity
Btu/h
243000
270000
297000
kW
71.2
79.1
87.1
Rated Heating
Capacity
Btu/h
226000
252000
275000
Cooling Power Input
kW
7.30+9.58
9.58+9.58
5.45+7.30+7.30
Heating Power Input
kW
7.85+10.42
10.42+10.42
5.80+7.85+7.85
Sound Pressure
Level
dB(A)
-
-
-
Power Supply
-
208/230V 3~ 60Hz
Compressor
Type
-
Inverter scroll type
Inverter scroll type
Inverter scroll type
Number
N
1+2
2+2
1+1+1
Motor Output
①
kW
-
-
-
Starting Method
-
Inverter
Inverter
Inverter
Operating Range
-
-
-
-
Refrigeration Oil
Brand
-
FVC68D or FV-68H
FVC68D or FV-68H
FVC68D or FV-68H
Fan
Type×Quantity
-
Propeller×(2+2)
Propeller×(2+2)
Propeller×(2+2+2)
Motor output
W
750×2+750×2
750×2+750×2
750×2+750×2+750×2
Starting method
-
Inverter
Inverter
Inverter
Air flow rate
m
3
/h
14000+14000
14000+14000
14000+14000+14000
cfm
8240+8240
8240+8240
8240+8240+8240
Max. external static
Pa
82
82
82
Содержание GC201808-III
Страница 36: ...GREE GMV5 HR HEAT RECOVERY UNITS 32 Circuit diagram of GMV Q144WM B1 F U Circuit diagram of GMV Q168WM B1 F U ...
Страница 87: ...GREE GMV5 HR HEAT RECOVERY UNITS 83 1 External Connection for Individual Units ...
Страница 92: ...GREE GMV5 HR HEAT RECOVERY UNITS 88 ...
Страница 227: ...GREE GMV5 HR HEAT RECOVERY UNITS 223 Troubleshooting ...
Страница 286: ...GREE GMV5 HR HEAT RECOVERY UNITS 282 Troubleshooting ...
Страница 314: ...GREE GMV5 HR HEAT RECOVERY UNITS 310 4 Loosen the screws on the compressor drive as shown in the figure below ...
Страница 362: ...JF00302879 ...