GREE GMV5 HR HEAT RECOVERY UNITS
1
PREFACE
This manual specifies safe operation requirements for GMV5 series VRF units from perspectives of
engineering and installation, commissioning and maintenance, as well as basic principles and
implementation methods. Professional operators must abide by relevant national (local) safety
requirements and technical specifications set forth in this manual during operations; otherwise, the air
conditioning system may fail or be damaged, and personnel safety accident may also occur.
SAFTY PRECAUTIONS
To prevent injury to the user or other people and property damage, the following instructions must
be followed.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all
safety messages that follow this symbol to avoid possible injury or death.
WARNING
This mark indicates procedures which, if improperly performed, might lead to the death or serious
injury of the user.
CAUTION
This mark indicates procedures which, if improperly performed, might possibly result in personal
harm to the user, or damage to property.
NOTICE is used to address practices not related to personal injury.
Installation
Have all electric work done by a licensed electrician according to "Electric Facility
Engineering Standard" and "Interior Wire Regulations" and the instructions given in this manual
and always use a special circuit.
If the power source capacity is inadequate or electric work is performed improperly, electric
shock or fire may result.
Ask the dealer or an authorized technician to install the air conditioner.
Improper installation by the user may result in water leakage, electric shock, or fire.
Always ground the product.
There is risk of fire or electric shock.
Always install a dedicated circuit and breaker.
Improper wiring or installation may cause fire or electric shock.
For re-installation of the installed product, always contact a dealer or an Authorized Service
Center.
There is risk of fire, electric shock, explosion, or injury.
Do not install, remove, or re-install the unit by yourself (customer).
There is risk of fire, electric shock, explosion, or injury.
Содержание GC201808-III
Страница 36: ...GREE GMV5 HR HEAT RECOVERY UNITS 32 Circuit diagram of GMV Q144WM B1 F U Circuit diagram of GMV Q168WM B1 F U ...
Страница 87: ...GREE GMV5 HR HEAT RECOVERY UNITS 83 1 External Connection for Individual Units ...
Страница 92: ...GREE GMV5 HR HEAT RECOVERY UNITS 88 ...
Страница 227: ...GREE GMV5 HR HEAT RECOVERY UNITS 223 Troubleshooting ...
Страница 286: ...GREE GMV5 HR HEAT RECOVERY UNITS 282 Troubleshooting ...
Страница 314: ...GREE GMV5 HR HEAT RECOVERY UNITS 310 4 Loosen the screws on the compressor drive as shown in the figure below ...
Страница 362: ...JF00302879 ...