Chapter 12 Troubleshooting
12-15
12
ErrorID
Meaning
How to deal with
Hex
Decimal
writing is out of the allowed word
register area.
(Valid range:
%MW0~%MW32767)
9022
36898
The start address of the local
buffer of word type for data
writing is within the allowed word
register area but can not meet the
alignment of word register
addresses.
(Valid range:
%MW0~%MW32767)
Modify the start address of the local buffer or
offset length.
9023
36899
The local buffer of word type for
the data reading has no enough
space to meet the specified
length of data.
(Valid range:
%MW0~%MW32767)
Modify the start address of the local buffer to
make it have enough space to meet the
specified data length.
9024
36900
The start address of the local
buffer of word type for data
writing is out of the allowed word
register area.
(Valid range:
%MW0~%MW32767)
Modify the start address of the local buffer
within the allowed word register area.
9025
36901
The start address of the local
buffer of word type for data
reading is within the allowed word
register area but can not meet the
alignment of word register
addresses.
(Valid range:
%MW0~%MW32767)
Modify the start address of the local buffer or
offset length.
9026
36902
The local buffer of bit type for
data writing has no enough space
to meet the specified length of
data.
(Range:
%QX0.0~%QX127.7,%MX0.0~%
MX65535.7)
Modify the start address of the local buffer to
make it have enough space to meet the
specified data length.
9027
36903
The start address of the local
buffer of bit type for data writing is
out of the allowed area.
(
Range:
%QX0.0~%QX127.7,%MX0.0~%
MX65535.7
)
Modify the start address of the local buffer
within the allowed area.
9028
36904
The local buffer of bit type for
data reading has no enough
space to meet the specified
length of data.
(%QX0.0~%QX127.7,%MX0.0~%
MX65535.7)
Modify the start address of the local buffer to
make it have enough space to meet the
specified data length.
9029
36905
The start address of the local
buffer of bit type for data reading
Modify the start address of the local buffer
within the allowed area.
Содержание DVP-15MC Series
Страница 16: ...1 1 1 Preface Table of Contents 1 1 Explanation of Symbols in This Manual 1 2 1 2 Revision History 1 3...
Страница 19: ...DVP 15MC Series Motion Controller Operation Manual 1 4 _1 MEMO...
Страница 20: ...2 1 2 Overview Table of Contents 2 1 Product Description 2 2 2 2 Functions 2 2 2 3 Profile and Components 2 3...
Страница 23: ...DVP 15MC Series Operation Manual 2 4 _2 MEMO...
Страница 31: ...DVP 15MC Series Motion Controller Operation Manual 3 8 _3 MEMO...
Страница 75: ...DVP 15MC Series Motion Controller Operation Manual 6 26 _6 MEMO...
Страница 87: ...DVP 15MC Series Motion Controller Operation Manual 7 12 _7 MEMO...
Страница 432: ...Chapter 8 Logic Instructions 8 345 8_ MEMO...
Страница 433: ...9 1 9 Chapter 9 Introductions of Axis Parameters Table of Contents 9 1 Description of Axis Parameters 9 2...
Страница 470: ...DVP 15MC Series Motion Controller Operation Manual 10 34 10 MEMO...
Страница 878: ...DVP 15MC Series Motion Controller Operation Manual 11 408 11 1 MEMO...
Страница 920: ...DVP 15MC Series Motion Controller Operation Manual A 16 A MEMO...
Страница 941: ...D 1 D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2...