Chapter 8 Logic Instructions
8-239
8_
Parameter Name
Timing for changing to TRUE
Timing for changing to FALSE
Done
When the configuration of
parameters is correct and
Execute
changes from FALSE
to TRUE.
When
Execute
changes from TRUE to
FALE.
Error
When the configuration of
parameters is incorrect and
Execute
changes from FALSE
to TRUE.
When
Execute
changes from TRUE to
FALE.
When
Execute
is re-triggered after the
parameter configuration is modified
correctly.
Output Update Timing Chart
E xec ute
Done
E rror
E rrorI D
Cas e1
Cas e2
Case 1
:
If the configuration of parameters is correct,
Done
changes from FASLE to TRUE as
Execute
changes from FASLE to TRUE.
Case 2
:
If an error occurs in the configuration of parameters,
Done
is FASLE and
Error
changes from
FALSE to TRUE as
Execute
changes from FASLE to TRUE.
Function
RS485_Link_Config is used to configure parameters for 485 communication Link. The firmware of V1.01
and above supports the function.
Precaution
1.
ObjType
is the data type of the read and written parameter. When
ObjType
is 0, it means to read and
write the word register of the slave. The range of Write_Length and Read_Length is 0~100 and the
values of Write_Length and Read_Length can not be 0 at the same time.
When
ObjType
is 1, it means to read and write the bit register of the slave. The range of Write_Length
and Read_Length is 0~256 and the values of Write_Length and Read_Length can not be 0 at the
same time. For local addresses, you can directly fill addresses, variables combined with addresses,
arrays combined with the starting addresses.
2.
For local address to fill the %MB address, you can only fill the low byte of the %MW address rather
than the high byte.
3.
For the register address of the slave, you can directly fill the MODBUS address and variable.
4.
For the offset in the word operation, the actual address is calculated by word. For the offset in the bit
operation, the actual address is calculated by bit.
For example:
Actual address calculated via word offset :
When the address is %MW0 and the offset is 15, the actual operation address is
%MW15=%MW (0+15).
Actual address calculated via bit offset:
When the address is %QW0 and the offset is 7, the actual operation address is %QX0.7.
5.
If you choose to read and write the word register of the slave, the %MW register of the local device
can be regarded as the storage register for reading and writing data. The range of the storage register
is %MW0~%MW32767. If the range is exceeded or other register is used, an error will occur in the
instruction.
Содержание DVP-15MC Series
Страница 16: ...1 1 1 Preface Table of Contents 1 1 Explanation of Symbols in This Manual 1 2 1 2 Revision History 1 3...
Страница 19: ...DVP 15MC Series Motion Controller Operation Manual 1 4 _1 MEMO...
Страница 20: ...2 1 2 Overview Table of Contents 2 1 Product Description 2 2 2 2 Functions 2 2 2 3 Profile and Components 2 3...
Страница 23: ...DVP 15MC Series Operation Manual 2 4 _2 MEMO...
Страница 31: ...DVP 15MC Series Motion Controller Operation Manual 3 8 _3 MEMO...
Страница 75: ...DVP 15MC Series Motion Controller Operation Manual 6 26 _6 MEMO...
Страница 87: ...DVP 15MC Series Motion Controller Operation Manual 7 12 _7 MEMO...
Страница 432: ...Chapter 8 Logic Instructions 8 345 8_ MEMO...
Страница 433: ...9 1 9 Chapter 9 Introductions of Axis Parameters Table of Contents 9 1 Description of Axis Parameters 9 2...
Страница 470: ...DVP 15MC Series Motion Controller Operation Manual 10 34 10 MEMO...
Страница 878: ...DVP 15MC Series Motion Controller Operation Manual 11 408 11 1 MEMO...
Страница 920: ...DVP 15MC Series Motion Controller Operation Manual A 16 A MEMO...
Страница 941: ...D 1 D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2...
Страница 966: ...DVP 15MC Series Motion Controller Operation Manual D 26 D MEMO...