DVP-15MC Series Motion Controller Operation Manual
8-264
_8
8.14.4.3
RS232_Link_Status
FB/FC
Explanation
Applicable model
FB
RS232_Link_Status is used to watch if an error occurs in the 232 link
which the number corresponds to or the slave replies with error codes.
DVP15MC11T
DVP15MC11T-06
R S232_Link_Status
Enable
RS232_Link_Status_instance
LinkNum
Valid
R S232_Link_Error
RS232_Link_ErrorID
Error
ErrorID
Input Parameters
Parameter
name
Function
Data type
Valid range
(Default)
Validation
timing
Enable
The instruction is validated when
Enable
changes from FALSE to
TRUE.
BOOL
TRUE or FALSE
(
FALSE
)
LinkNum
The number of the link to be watched.
UINT
1~24
(The variable value
must be set)
When
Enable
changes from
FALSE to TRUE
Output Parameters
Parameter name
Function
Data
type
Valid range
Valid
TRUE when the outputs of the instruction are valid.
BOOL
TRUE / FALSE
RS232_Link_Error
TRUE when an error occurs in the corresponding link. It
is valid when
Error
is FALSE.
BOOL
TRUE / FALSE
RS232_Link_ErrorID
Outputs communication error code. See error codes and
their meanings as below:
1: Unidentified function code
2: The address in the response message from the slave
is different from the configured address.
3: The length of received data in the response message
from the slave is inconsistent with the configured
length.
4: Data-receiving timeout
5: Checksum error
6: The configured lengths of data to be read and written
are both 0.
7: The length of the data that is actually received
exceeds the max. received data length.
8: Data-sending timeout
16#80+ exception code: the exception code from the
slave
WORD
Error
TRUE when an error occurs in the instruction inputs.
BOOL
TRUE / FALSE
ErrorID
Contains error codes when an error occurs in the
instruction execution. Please refer to section 12.2 for the
corresponding error code.
WORD
Содержание DVP-15MC Series
Страница 16: ...1 1 1 Preface Table of Contents 1 1 Explanation of Symbols in This Manual 1 2 1 2 Revision History 1 3...
Страница 19: ...DVP 15MC Series Motion Controller Operation Manual 1 4 _1 MEMO...
Страница 20: ...2 1 2 Overview Table of Contents 2 1 Product Description 2 2 2 2 Functions 2 2 2 3 Profile and Components 2 3...
Страница 23: ...DVP 15MC Series Operation Manual 2 4 _2 MEMO...
Страница 31: ...DVP 15MC Series Motion Controller Operation Manual 3 8 _3 MEMO...
Страница 75: ...DVP 15MC Series Motion Controller Operation Manual 6 26 _6 MEMO...
Страница 87: ...DVP 15MC Series Motion Controller Operation Manual 7 12 _7 MEMO...
Страница 432: ...Chapter 8 Logic Instructions 8 345 8_ MEMO...
Страница 433: ...9 1 9 Chapter 9 Introductions of Axis Parameters Table of Contents 9 1 Description of Axis Parameters 9 2...
Страница 470: ...DVP 15MC Series Motion Controller Operation Manual 10 34 10 MEMO...
Страница 878: ...DVP 15MC Series Motion Controller Operation Manual 11 408 11 1 MEMO...
Страница 920: ...DVP 15MC Series Motion Controller Operation Manual A 16 A MEMO...
Страница 941: ...D 1 D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2...
Страница 966: ...DVP 15MC Series Motion Controller Operation Manual D 26 D MEMO...