DVP-15MC Series Motion Controller Operation Manual
8-198
_8
8.14.2.3
ETH_Link_Status
FB/FC
Explanation
Applicable model
FB
ETH_Link_Status is used to watch if an error occurs in the MODBUS
TCP link which the number corresponds to or if the slave replies with
error codes.
DVP15MC11T
DVP15MC11T-06
E TH _Link_Status
Enable
E T H_Link_Status_instance
LinkNum
Valid
ET H_Error
E TH_ErrorID
Error
ErrorID
Input Parameters
Parameter name
Function
Data type
Valid range
(Default)
Validation timing
Enable
The instruction is
validated when
Enable
changes from FALSE to
TRUE.
BOOL
TRUE or FALSE
(
FALSE
)
LinkNum
The number of MODBUS
TCP link to be monitored.
UINT
1~16
(
0
)
When
Enable
changes from
FALSE to TRUE
Output Parameters
Parameter name
Function
Data type
Valid range
Valid
TRUE when the outputs of the instruction are
valid.
BOOL
TRUE / FALSE
ETH_Error
TRUE when an error occurs in the MODBUS TCP
data exchange.
BOOL
TRUE / FALSE
ETH_ErrorID
MODBUS TCP data exchange error code.
Refer to the table in the following
Function
section. If the
ETH_ErrorID
value is 1~10, refer to
the relevant slave manual for corresponding error
ID explanation.
WORD
Error
TRUE when an error occurs in the instruction
execution.
BOOL
TRUE / FALSE
ErrorID
Contains error codes when an error occurs in the
instruction execution. Please refer to section 12.2
for the corresponding error code.
WORD
Output Update Timing
Parameter
Name
Timing for changing to TRUE
Timing for changing to FALSE
Valid
When
Enable
changes to TRUE.
When
Enable
changes from TRUE to
FALSE.
ETH_Error
When an error occurs in MODBUS
TCP data exchange.
When
Enable
changes from TRUE to
FALSE.
Содержание DVP-15MC Series
Страница 16: ...1 1 1 Preface Table of Contents 1 1 Explanation of Symbols in This Manual 1 2 1 2 Revision History 1 3...
Страница 19: ...DVP 15MC Series Motion Controller Operation Manual 1 4 _1 MEMO...
Страница 20: ...2 1 2 Overview Table of Contents 2 1 Product Description 2 2 2 2 Functions 2 2 2 3 Profile and Components 2 3...
Страница 23: ...DVP 15MC Series Operation Manual 2 4 _2 MEMO...
Страница 31: ...DVP 15MC Series Motion Controller Operation Manual 3 8 _3 MEMO...
Страница 75: ...DVP 15MC Series Motion Controller Operation Manual 6 26 _6 MEMO...
Страница 87: ...DVP 15MC Series Motion Controller Operation Manual 7 12 _7 MEMO...
Страница 432: ...Chapter 8 Logic Instructions 8 345 8_ MEMO...
Страница 433: ...9 1 9 Chapter 9 Introductions of Axis Parameters Table of Contents 9 1 Description of Axis Parameters 9 2...
Страница 470: ...DVP 15MC Series Motion Controller Operation Manual 10 34 10 MEMO...
Страница 878: ...DVP 15MC Series Motion Controller Operation Manual 11 408 11 1 MEMO...
Страница 920: ...DVP 15MC Series Motion Controller Operation Manual A 16 A MEMO...
Страница 941: ...D 1 D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2...
Страница 966: ...DVP 15MC Series Motion Controller Operation Manual D 26 D MEMO...