- 7 -
:(/',1*0$&+,1('(6&5,37,21
&21752/$'-8670(17$1'&211(&7,1*'(9,&(6
:(/',1*0$&+,1()LJ%
$WWKHIURQW
1- Control panel (see description);
2- Torch connection and SPOOL GUN (single torch version only);
3- PUSH PULL, CONTROL and SPOOL GUN (single torch version only) control
cable connector;
4- Positive (+) quick coupling for connecting the welding cable;
5- Negative (-) quick coupling for connecting the welding cable;
6- Earth return cable and clamp;
7- SPOOL GUN (optional);
8- Welding cable and torch;
9- Return connector (red) for cooling liquid (for the AQUA version only);
10- Input connector (blue) for cooling liquid (for the AQUA version only);
11- Liquid tank cap (for the AQUA version only).
$WWKHEDFN
12- Main ON/OFF switch;
13- Power cable;
14- Hose connector for torch protective gas;
15- G.R.A. protection fuse (R.A. version only);
16- Pipe connector for torch shielding gas T1;
17- Pipe connector for torch shielding gas T2;
18- Pipe connector for torch shielding gas T3;
:(/',1*0$&+,1(&21752/3$1(/)LJ&
1- TFT Display.
2- Manual wire jog button. This jogs the wire forward in the torch sheath without
having to touch the torch button; this is a momentary action and the speed is set
DQG¿[HG
0DQXDOJDVVROHQRLGYDOYHVWDUWEXWWRQ7KLVHQDEOHVWKHÀRZRIJDVSLSHEOHHGV
ÀRZUDWHDGMXVWPHQWZLWKRXWWKHQHHGWRXVHWKHWRUFKEXWWRQRQFHSUHVVHGWKH
solenoid valve remains enabled for 10 seconds or until it is pressed again.
4- Multi-function button:
-
: access to the main menu;
-
: enabling/disabling of the parameter to be displayed on the welding
screen;
5- Multi-function knob:
- rotate the knob to scroll through the various menu items;
- press to access the selected item, rotate to change the setting, press again to
FRQ¿UPWKHYDOXH
- press and hold for at least 3 seconds to set the variables in synergic mode
(material type, wire diameter, gas type, 2T, 4T, 4T bi-level, SPOT).
6- Multi-function button:
-
: access to the parameter to be displayed on the welding screen;
-
: back to the main menu.
-
FRQ¿UPDWLRQRIWKHFKRVHQYDOXHV
7- USB port.
,167$//$7,21
:$51,1* $// ,167$//$7,21 23(5$7,216 $1' (/(&75,&$/
&211(&7,216 0867 $/:$<6 %( &$55,(' 287 :,7+ 7+( :(/',1*
0$&+,1(6:,7&+('2))$1'',6&211(&7(')5207+(32:(56833/<
7+((/(&75,&&211(&7,216086721/<%(&$55,('287%<(;3(5725
48$/,),('7(&+1,&,$16
$66(0%/<)LJ'''DE
Unpack the welding machine and assemble the separate parts included in the
package.
$VVHPEOLQJWKHFODPSUHWXUQFDEOH)LJ(
$VVHPEOLQJWKHZHOGLQJFDEOHHOHFWURGHKROGHUFODPS),*)
*5$LQVWDOODWLRQ$48$YHUVLRQRQO\VHHLQVWUXFWLRQPDQXDOLQVLGHWKHZDWHU
FRROLQJV\VWHP
326,7,21,1*7+(:(/',1*0$&+,1(
Choose the place where the welding machine is to be installed so that there are no
obstructions to the cooling air inlets and outlets; at the same time make sure that
conductive dust, corrosive vapours, humidity etc. cannot be drawn into the machine.
Leave at least 250 mm of free space all around the welding machine.
:$51,1* 3RVLWLRQ WKH ZHOGLQJ PDFKLQH RQ D OHYHO VXUIDFH ZLWK
VXI¿FLHQW ORDGEHDULQJ FDSDFLW\ VR WKDW LW FDQQRW EH WLSSHG RYHU RU VKLIW
GDQJHURXVO\
&211(&7,21727+(0$,132:(56833/<
- Before making any electrical connection, check the rating plate data on the welding
machine to make sure they correspond to the voltage and frequency of the available
power supply where the machine is to be installed.
- The welding machine must be connected only and exclusively to a power supply with
the neutral conductor connected to earth.
- To guarantee protection against indirect contact use the following types of residual
current devices:
- Type
A
(
) for single-phase machines.
- Type B (
) for 3-phase machines.
- In order to satisfy the requirements of the EN 61000-3-11 (Flicker) standard we
recommend connecting the welding machine to the interface points of the main
power supply that have an impedance of less than Zmax = 0.24 ohm.
- The welding machine is not within the requirements of standard IEC/EN 61000-3-12.
If it is connected to a public power mains, the installer or the user is responsible for
checking the welding machine can be connected (if necessary, consult the mains
power supply provider).
3OXJDQGVRFNHW
(1~)
Connect the power cable plug to a mains socket equipped with fuses or an automatic
VZLWFKWKHVSHFL¿FHDUWKOXJPXVWEHFRQQHFWHGWRWKHHDUWKFRQGXFWRU\HOORZJUHHQ
of the power supply line.
(3~)
Connect a standard plug (3P + E) to the power supply cable with adequate capacity
DQGXVHDPDLQVVRFNHWHTXLSSHGZLWKIXVHVRUDQDXWRPDWLFVZLWFKWKHVSHFL¿FHDUWK
lug must be connected to the earth conductor (yellow-green) of the power supply line.
Table 1
7$%
provides the recommended values in amperes of the line slow blow
fuses chosen based on the max. nominal current supplied by the welding machine,
and at the power supply nominal voltage.
:$51,1* 1RQFRPSOLDQFH ZLWK WKH DERYH UHJXODWLRQV UHQGHUV WKH
PDQXIDFWXUHU¶VVDIHW\V\VWHPFODVV,LQHI¿FLHQWZLWKUHVXOWLQJVHULRXVULVNVWR
SHRSOHHJHOHFWULFVKRFNDQGWKLQJVHJ¿UH
:(/',1*&,5&8,7&211(&7,21
5HFRPPHQGDWLRQV
$77(17,21
%()25(
&$55<,1*
287
7+(
)2//2:,1*
&211(&7,216 0$.( 685( 7+( :(/',1* 0$&+,1( ,6 2)) $1'
',6&211(&7(')5207+(0$,16
Table 1 (TAB. 1) gives the recommended values for welding cables (in mm
2
) according
to the maximum energy supplied by the welding machine.
In addition:
- Fully rotate the welding cable connectors in the quick couplings (if present), to
guarantee perfect electric contact; if this is not the case the connectors will overheat
ZLWKFRQVHTXHQWIDVWGHWHULRUDWLRQDQGORVVRIHI¿FLHQF\
- Use the shortest welding cables possible.
- Do not use metal structures that are not part of the workpiece to replace the welding
current return cable; this can endanger safety and give unsatisfactory welding
results.
:(/',1*&,5&8,7&211(&7,21,10,*0$*02'(
&RQQHFWLQJWKHJDVERWWOHLIXVHG
- Gas bottle that can be loaded onto the supporting surface of the trolley: max. 30 kg.
- When using Argon gas or an Argon/CO
2
mixture, screw the pressure reducer(*) onto
the gas bottle valve, placing the relative pressure reducing valve supplied as an
accessory.
- Connect the gas input hose to the pressure reducing valve and tighten the strip.
- Loosen the adjustment ring nut of the pressure reducing valve before opening the
gas bottle valve.
(*) Accessory to be purchased separately if not supplied with the product.
&RQQHFWLQJWKHZHOGLQJFXUUHQWUHWXUQFDEOH
Connect the cable to the piece to be welded or the metal bench on which the workpiece
is placed, as close as possible to the joint being worked.
7RUFK)LJ%
Insert the torch (B-8) into the dedicated connector (B-2), fully tightening the locking
ULQJQXWPDQXDOO\3UHSDUHWKHWRUFKWRUHFHLYHWKHZLUHIRUWKH¿UVWWLPHUHPRYLQJWKH
nozzle and the contact pipe, to make exiting easier.
Connect the outside cooling pipes to the relative plugs and pay attention to the
following:
: LIQUID INPUT (Cold - blue connector)
: RETURN LIQUID (Hot - red connector)
6SRROJXQVLQJOHWRUFKYHUVLRQRQO\)LJ%
Insert the spool gun (B-6) into the dedicated connector (B-2), fully tightening the
locking ring nut manually. Also insert the control cable connector into the relative
socket (B-5). The welding machine automatically acknowledges the spool gun.
:(/',1*&,5&8,7&211(&7,21,17,*02'(
&RQQHFWLQJWKHJDVERWWOH
- Screw the pressure reducer onto the gas bottle valve, placing the relative reduction
supplied as an accessory between them;
- Connect the gas input hose to the pressure reducing valve and tighten the supplied
strip.
- Loosen the adjustment ring nut of the pressure reducing valve before opening the
gas bottle valve.
- Open the gas bottle and adjust the quantity of gas (l/min.) according to the
UHFRPPHQGHGXVDJHGDWDVHHWDEOH7$%WKHJDVÀRZFDQEHDGMXVWHGZKLOH
welding, always using the ring nut of the pressure reducer. Check the seal of the
hoses and connections.
$77(17,21$OZD\VFORVHWKHJDVERWWOHYDOYHZKHQ\RXKDYH¿QLVKHG
ZRUNLQJ
&RQQHFWLQJWKHZHOGLQJFXUUHQWUHWXUQFDEOH
- Connect it to the piece to be welded or the metal bench on which the workpiece is
placed, as close as possible to the joint being worked. Connect this cable to the
clamp with the symbol (+) (Fig. B-7).
7RUFK
- Insert the current cable into the relative quick coupling (-) (Fig. B-8). Connect the gas
hose of the torch to the gas bottle
:(/',1*&,5&8,7&211(&7,21,100$02'(
Almost all the coated electrodes are connected to the positive pole (+) of the generator,
with an exception for acid coated electrodes, which must be connected to the negative