Service Manual
9-11
Checks and Adjustments
9
6.
With the cap/wipe/purge alignment tool, check that each end of the
cap/wipe/purge unit is the same distance from the top edge of the
printhead faceplate. This ensures that the cap/wipe/purge unit is
parallel to the printhead.
7.
If the cap/wipe/purge unit is skewed to the printhead faceplate, use a
2 mm hex wrench to loosen the two set screws on the right
cap/wipe/purge shaft pulley. Rotate the shaft to bring the
cap/wipe/purge unit into alignment and tighten pulley.
8.
Reassemble the printer and make a test print or proceed to the
following procedure.
Figure 9-5 Aligning the cap/wipe/purge unit to the printhead
Parts omitted from
drawing for clarity
9661-107
Rubber seal
Faceplate
Cap/wipe/purge
alignment tool
Adjust alignment
by loosening
this pulley