9-25
Descriptions on the clearing methods of abnormal alarms:
1. Switch reset: The following two methods can be used to clear abnormal alarms:
(a)
Digital input contact reset: When the abnormality is eliminated, first release the
SON
action
of the digital input contact (which is releasing the motor excitation status), then make the
digital input contact
ALRS
act to clear the abnormal alarm and make the driver resume
normal operation.As for the digital input contact effective logic, please set them by referring
to
“5-6-1 Digital
input/output contact function plan”.
(b)
Button reset: When the abnormality is eliminated, first release the
SON
action of the digital
input contact (which is releasing the motor excitation status), then press the
and
buttons simultaneously to clear the abnormal alarm, and make the driver resume normal
operation.
2. Power reset: When the abnormality is eliminated,
rebooting
is required (turn off the power and then
input power again) to clear the abnormal alarm and make the driver resume normal operation.
It is
strongly recommended to release the digital input contact SON action first (releasing the
motor’s excitation status) when using power reset to clear abnormal alarms.
Caution
Before clearing abnormal alarms, confirm that the controller is not sending commands to the
driver in order to prevent the motor from going out of control
!
Summary of Contents for JSDG2S Series
Page 1: ......
Page 44: ...2 5 400V Class...
Page 303: ...5 178 2 3 1...
Page 693: ...10 7 10 2 Servo Drive Dimension 1 JSDG2S 10A 15A E 200V Class 2 JSDG2S 20A 30A E 200V Class...
Page 694: ...10 8 3 JSDG2S 10A 15A EL 200V Class 4 JSDG2S 20A 30A EL 200V Class...
Page 695: ...10 9 5 JSDG2S 10A 15A L 200V class 6 JSDG2S 20A 30A L 200V Class...
Page 700: ...10 14 Up to 130 Frame Series Up to 220 Frame Series...
Page 704: ...10 18 Up to 220 Frame Series Up to 130 Frame Series LL Without brake LL With brake IH Series...
Page 713: ...11 1 Chap 11 Appendix 11 1 Manual Revision History 11 2...
Page 718: ......