7-24
Cn007
Speed Reached Determined Value
【
5-3-8
】
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
Rated speed*1/3
rpm
0 ~ 1.5*Rated Speed
--
--
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
0008H 2007H 2007H
--
--
--
O
O
Setting Description: When the Forward or Reverse Speed exceeds the speed set by Cn007 (Speed Reached Determined
Value), Digital Output Contact INS activates
Cn008.0 Brake Mode
【
5-6-4
】
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
2 --
0
~
5
--
--
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
0009H
2008H
2008H
O O O O O
Setting Description: The Brake Combination of Servo off, Emergency Stop (EMC), and when CCW/CW Drive is
Prohibited.
Setting
Description
Dynamic Brake
Mechanical Brake
0 No
No
1 No
Yes
2 Yes
No
3 Yes
Yes
4 No
(under
100rpm)
No
5 No
(under
100rpm)
Yes
Attention!
When
CCW/CW generates drive prohibition, the setting of if use dynamic brake Cn009 is prior to
Cn008, i.e. if Cn008 is set as 0 or 1 (without dynamic brake) and Cn009 is set as 1 (with dynamic brake), the
dynamic brake will be implemented eventually.
Summary of Contents for JSDG2S Series
Page 1: ......
Page 44: ...2 5 400V Class...
Page 303: ...5 178 2 3 1...
Page 693: ...10 7 10 2 Servo Drive Dimension 1 JSDG2S 10A 15A E 200V Class 2 JSDG2S 20A 30A E 200V Class...
Page 694: ...10 8 3 JSDG2S 10A 15A EL 200V Class 4 JSDG2S 20A 30A EL 200V Class...
Page 695: ...10 9 5 JSDG2S 10A 15A L 200V class 6 JSDG2S 20A 30A L 200V Class...
Page 700: ...10 14 Up to 130 Frame Series Up to 220 Frame Series...
Page 704: ...10 18 Up to 220 Frame Series Up to 130 Frame Series LL Without brake LL With brake IH Series...
Page 713: ...11 1 Chap 11 Appendix 11 1 Manual Revision History 11 2...
Page 718: ......