5-98
Tool Number Position Contact Input Table:
DI
Tool Number
POS6
POS5
POS4
POS3
POS2
POS1
Tool Number 1
OFF
OFF
OFF
OFF
OFF
OFF
Tool Number 2
OFF
OFF
OFF
OFF
OFF
ON
:
:
:
:
:
:
:
Tool Number 11
OFF
OFF
ON
OFF
ON
OFF
Tool Number 12
OFF
OFF
ON
OFF
ON
ON
:
:
:
:
:
:
:
Tool Number 63
ON
ON
ON
ON
ON
OFF
Tool Number 64
ON
ON
ON
ON
ON
ON
OFF means the contact does not function (Open); ON means the contact functions (Closed).
Absolute Value Type Encoder built-in Position Memory can permanently memorize the position
information of each tool number. When start the machine after powered off, the Driver will
automatically output the (DO) status to the controller; the controller performs binary decoding on the
signal to obtain the current position of tool number, and does not need to perform the Return to Origin
operation. If the 64th tool will be used, the 7th point INP signal must be added with P1~P6 to conduct
Output Determination.
When in first tool position, the Digital Output Signals P1~P6 and INP Signal will all be output,
when the Digital Output Signals P1~P6 and INP Signal are not all output, indicates the tool number is
no longer in the range, and timing of tool number is not in the range:
1. First time use of the Tool Magazine Mode; the first time use of the Cutter Setup Return to Zero
operation, to be able to operate correctly.
2. In the Process the Servo Motor moves to the next tool number position.
Tool Magazine Control Tool Number Position Contact Output Table:
DO
Tool Number
P6
P5
P4
P3
P2
P1
INP
Not
in
the
Range OFF OFF OFF OFF OFF OFF OFF
Tool Number 1
ON
ON ON ON ON ON ON
Tool Number 2
ON
ON ON ON ON OFF ON
:
:
:
:
:
:
:
ON
Tool
Number
11 ON ON OFF ON OFF ON ON
Tool Number 12
ON
ON OFF ON OFF OFF ON
:
:
:
:
:
:
:
ON
Tool
Number
63 OFF OFF OFF OFF OFF ON ON
Tool
Number
64 OFF OFF OFF OFF OFF OFF ON
OFF means the contact does not function (Open); ON means the contact functions (Closed).
Summary of Contents for JSDG2S Series
Page 1: ......
Page 44: ...2 5 400V Class...
Page 303: ...5 178 2 3 1...
Page 693: ...10 7 10 2 Servo Drive Dimension 1 JSDG2S 10A 15A E 200V Class 2 JSDG2S 20A 30A E 200V Class...
Page 694: ...10 8 3 JSDG2S 10A 15A EL 200V Class 4 JSDG2S 20A 30A EL 200V Class...
Page 695: ...10 9 5 JSDG2S 10A 15A L 200V class 6 JSDG2S 20A 30A L 200V Class...
Page 700: ...10 14 Up to 130 Frame Series Up to 220 Frame Series...
Page 704: ...10 18 Up to 220 Frame Series Up to 130 Frame Series LL Without brake LL With brake IH Series...
Page 713: ...11 1 Chap 11 Appendix 11 1 Manual Revision History 11 2...
Page 718: ......