5-25
5-3-2 Analog speed command
JSDG2S-E(L) does not have this function
Adjust the slope of Voltage Command relative to the Speed Command in coordination with the
Analog Speed Command Proportioner.
Sn216 Analog speed command proportioner
JSDG2S-E(L) does not have this function
Initial Value
Unit
Setting Range
Effective
RS-485 Address
Rated Speed rpm/10V
100 ~ 10000
Effective after Set
0210H
Setting Description: Used to adjust the slope of Voltage Command relative to the Speed Command.
Setting Example:
(1) If
Sn216
is set to 3000, it means Analog Input Voltage 10V corresponds to 3000rpm Speed
Command; if Analog Input Voltage is 5V at this time, then it corresponds to 1500rpm Speed
Command.
(2) If
Sn216
is set to2000, it means Analog Input Voltage 10V corresponds to 2000rpm Speed
Command; if Analog Input Voltage is 5V at this time, then it corresponds to 1000rpm Speed
Command.
Note: The displayed speed needs to be determined according to the different motors.