5-130
5-6-3 Contact Auxiliary Function
The User can select whether the corresponding function of Digital Input Contacts
SON
,
CCWL
and
CWL
is activated. The setting is as follows:
Cn002.0 Contact Auxiliary Function - Digital Input Contact SON Function
Selection
Initial Value
Unit
Setting Range
Effective
RS-485 Address
0
--
0 ~ 1
Power Re-set
0002H
Setting Description:
Setting
Description
0
Control servo activation by digital input
contact
SON
.
1
Do not control servo activation by digital
input contact
SON
; activate servo
immediately when the power is on.
Remark: Invalid under EtherCAT & CANopen mode
Cn002.1 Contact Auxiliary Functions--Digital Input Contact CCWL and CWL
Function Selection
Initial Value
Unit
Setting Range
Effective
RS-485 Address
0
--
0 ~ 1
Power Re-set
0002H
Setting Description:
Setting
Description
0
Control CCW and CW Drive Prohibit by Digital
Input Contacts CCWL and CWL.
1
Do not control CCW and CW Drive Prohibit by
Digital Input Contacts CCWL and CWL; ignore
CCW and CW Drive Prohibit Functions.
Summary of Contents for JSDG2S Series
Page 1: ......
Page 44: ...2 5 400V Class...
Page 303: ...5 178 2 3 1...
Page 693: ...10 7 10 2 Servo Drive Dimension 1 JSDG2S 10A 15A E 200V Class 2 JSDG2S 20A 30A E 200V Class...
Page 694: ...10 8 3 JSDG2S 10A 15A EL 200V Class 4 JSDG2S 20A 30A EL 200V Class...
Page 695: ...10 9 5 JSDG2S 10A 15A L 200V class 6 JSDG2S 20A 30A L 200V Class...
Page 700: ...10 14 Up to 130 Frame Series Up to 220 Frame Series...
Page 704: ...10 18 Up to 220 Frame Series Up to 130 Frame Series LL Without brake LL With brake IH Series...
Page 713: ...11 1 Chap 11 Appendix 11 1 Manual Revision History 11 2...
Page 718: ......