5-83
Cn011/Cn057
CW Direction Torque Command Limit Value Stage 1 / Stage 2
Initial Value
Unit
Setting Range
Effective
RS-485 Address
-300 ~ -200
Note)
%
-300 ~ 0
Effective after Set
Each Parameter is
different
Note)
Default and setting range of parameter
Cn010/Cn056/Cn011/Cn057 vary by driver model. Refer
to “7-3-1 System parameters (Cn0
□□
)” for details.
Cn058 The Delay Time of Torque Limit Stage 1 switch to Torque Limit Stage 2
Initial Value
Unit
Setting Range
Effective
RS-485 Address
0
4ms
0 ~ 32767
--
003DH
Setting Description: After the digital output contact INP delays according to the time set by Cn058,
the torque limit switch from (Cn010, Cn011) to (Cn056, Cn057) and from
(Cn056, Cn057) to (Cn010, Cn011) after PTRG operates.
Before V1.76, External Pulse Command Mode does not support two-stage Torque Limit
Signal Trigger
DI-PTRG
Signal Trigger Delay
(Pn334)
Motor Speed Command
Positioning Completion Signal
DO-INP
Pn334
Servo Excitation
DI-SON
Torque Limit Switching Time
(Cn058)
Cn058
Stage 2 Torque
Torque Limit Value
Stage 1 Torque
Stage 2 Torque
Summary of Contents for JSDG2S Series
Page 1: ......
Page 44: ...2 5 400V Class...
Page 303: ...5 178 2 3 1...
Page 693: ...10 7 10 2 Servo Drive Dimension 1 JSDG2S 10A 15A E 200V Class 2 JSDG2S 20A 30A E 200V Class...
Page 694: ...10 8 3 JSDG2S 10A 15A EL 200V Class 4 JSDG2S 20A 30A EL 200V Class...
Page 695: ...10 9 5 JSDG2S 10A 15A L 200V class 6 JSDG2S 20A 30A L 200V Class...
Page 700: ...10 14 Up to 130 Frame Series Up to 220 Frame Series...
Page 704: ...10 18 Up to 220 Frame Series Up to 130 Frame Series LL Without brake LL With brake IH Series...
Page 713: ...11 1 Chap 11 Appendix 11 1 Manual Revision History 11 2...
Page 718: ......