7-34
Cn020 Switch delay time 2 of two stage gain mode
【
6-7-2
】
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
0 0.2ms 0
~
10000
--
--
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
0016H
2014H
2014H
O O O O --
Setting Description: When using the Two Stage Gain Mode, the Delay Time from the Second Stage Gain to the First Stage
Gain can be set.
Cn021 Switch condition of two stage gain mode (torque command)
【
6-7-2
】
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
200 %
0
~
399
--
--
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
0017H
2015H
2015H
O O O O --
Setting Description: Set Cn015.1=0 first, when the Torque Command is less than the Cn021 switching condition, use the
first stage gain control; when the Torque Command is greater than the Cn021 switching condition,
then switch to the second stage gain control. If the Torque Command is less than the Cn021 switching
condition again, it will switch to the first stage gain control in accordance with Cn020 Switching
Delay Time.
Cn022 Switch condition of two stage gain mode (speed command)
【
6-7-2
】
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
0
rpm
0 ~ 1.5*Rated Speed
--
--
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
0018H
2016H
2016H
O O O O --
Setting Description: Set Cn015.1=1 first, when the Speed Command is less than the Cn022 switching condition, use the
first stage gain control; when the Speed Command is greater than the Cn022 switching condition,
then switch to the second stage gain control. If the Speed Command is less than the Cn022 switching
condition again, it will switch to the first stage gain control in accordance with Cn020 Switching
Delay Time.
Cn023 Switch condition of two stage gain mode (acceleration command)
【
6-7-
2
】
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
0 rps/s 0
~
18750
--
--
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
0019H
2017H
2017H
O O O O --
Summary of Contents for JSDG2S Series
Page 1: ......
Page 44: ...2 5 400V Class...
Page 303: ...5 178 2 3 1...
Page 693: ...10 7 10 2 Servo Drive Dimension 1 JSDG2S 10A 15A E 200V Class 2 JSDG2S 20A 30A E 200V Class...
Page 694: ...10 8 3 JSDG2S 10A 15A EL 200V Class 4 JSDG2S 20A 30A EL 200V Class...
Page 695: ...10 9 5 JSDG2S 10A 15A L 200V class 6 JSDG2S 20A 30A L 200V Class...
Page 700: ...10 14 Up to 130 Frame Series Up to 220 Frame Series...
Page 704: ...10 18 Up to 220 Frame Series Up to 130 Frame Series LL Without brake LL With brake IH Series...
Page 713: ...11 1 Chap 11 Appendix 11 1 Manual Revision History 11 2...
Page 718: ......