6-47
6-14 Disturbance Observer
Use the disturbance observer to estimate the external disturbance torque in order to reduce the impact
of disturbance torque, and further reduce speed ripples.
tn845.2 Disturbance observer speed feedback selection
Initial Value
Unit
Setting Range
Effective
RS-485 Address
0
--
0 ~ 3
Effective after Set
132DH
Setting description:
Setting
Description
0
No sampling and calculation
1
5kHz sampling and calculation
2
2.5kHz sampling and calculation
3
1.25kHz sampling and calculation
tn846 Disturbance observer filter constant
Initial Value
Unit
Setting Range
Effective
RS-485 Address
30
--
0 ~ 1000
Effective after Set
132EH
Setting description: Disturbance observer filter constant
Torque command
Torque control
Motor
External disturbance force
Load
Cn025 load inertia ratio
Load model
Filter
tn847 Disturbance observer limit value
tn846 Disturbance observer filter constant
tn845.2 Disturbance observer speed feedback selection
Summary of Contents for JSDG2S Series
Page 1: ......
Page 44: ...2 5 400V Class...
Page 303: ...5 178 2 3 1...
Page 693: ...10 7 10 2 Servo Drive Dimension 1 JSDG2S 10A 15A E 200V Class 2 JSDG2S 20A 30A E 200V Class...
Page 694: ...10 8 3 JSDG2S 10A 15A EL 200V Class 4 JSDG2S 20A 30A EL 200V Class...
Page 695: ...10 9 5 JSDG2S 10A 15A L 200V class 6 JSDG2S 20A 30A L 200V Class...
Page 700: ...10 14 Up to 130 Frame Series Up to 220 Frame Series...
Page 704: ...10 18 Up to 220 Frame Series Up to 130 Frame Series LL Without brake LL With brake IH Series...
Page 713: ...11 1 Chap 11 Appendix 11 1 Manual Revision History 11 2...
Page 718: ......