7-52
Cn089 Regenerative Resistor Resistance Setting
【
5-6-7
】
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
System setting
x0.1 ohm
0 ~ 10000
--
--
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
005CH
2059H
2059H
O O O O O
Setting description: Please set the resistance value of the regenerative resistor used.
Note) Setting 0 means that regeneration is not used.
Cn090.3 No detection of linear motor encoder Z phase disconnection function
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
0 -- 0
~
1
★
●
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
005DH
205AH
205AH
O O O O O
Setting description:
Setting
Description
0
Disable the do not detect pulse encoder Z phase disconnection function
1
Enable the do not detect pulse encoder Z phase disconnection function
Cn097.0 Motor disconnection protection flag
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
0 --
0
~
1
--
--
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
0064H
2061H
2061H
O O O O O
Setting Description:
Cn097.1 EMC stop function selection
【
5-6-18
】
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
0 --
0
~
1
--
--
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
0064H
2061H
2061H
O O O O O
Setting
Description
0
Disable motor cable disconnection protection
1
Enable motor cable disconnection protection.
Note: When speed command is 0, it is determined
by position error. Maximum and minimum can be
set by Pn308 & Pn309.
Summary of Contents for JSDG2S Series
Page 1: ......
Page 44: ...2 5 400V Class...
Page 303: ...5 178 2 3 1...
Page 693: ...10 7 10 2 Servo Drive Dimension 1 JSDG2S 10A 15A E 200V Class 2 JSDG2S 20A 30A E 200V Class...
Page 694: ...10 8 3 JSDG2S 10A 15A EL 200V Class 4 JSDG2S 20A 30A EL 200V Class...
Page 695: ...10 9 5 JSDG2S 10A 15A L 200V class 6 JSDG2S 20A 30A L 200V Class...
Page 700: ...10 14 Up to 130 Frame Series Up to 220 Frame Series...
Page 704: ...10 18 Up to 220 Frame Series Up to 130 Frame Series LL Without brake LL With brake IH Series...
Page 713: ...11 1 Chap 11 Appendix 11 1 Manual Revision History 11 2...
Page 718: ......