7-62
Tn115 Internal Reverse Rotational Speed Limit
【
5-2-6
】
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
-100
rpm
-1.5*rated rotational speed ~ 0
--
--
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
010FH
-
-
- - - - O
Setting Description: Set Tn101.2=1, switch the Forward Reverse Rotational Speed Limit value Speed Control Parameter
by Positive and Negative Torques.
Tn116 Analog torque command filter
【
5-2-1
】
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
0 Hz
0
~
5000
--
--
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
0110H
-
-
O O O O O
Setting Description: Set TIC analog torque command stop frequency, if set 2500, it means 2500Hz.
Tn117 Torque command straight line deceleration constant
【
5-2-3
】
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
1 ms
1
~
50000
▲
--
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
0111H
2111H-
2111H-
- - - - O
Setting Description: The definition of torque command straight line deceleration constant is the time for the torque
command to decrease in a straight line from the rated torque to zero.
Tn118 INT Torque arrival signal delay time
【
5-2-1
】
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
0 ms
1
~
50000
--
--
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
0112H
2112H-
2112H-
- - - - O
Setting Description: When the Tn108 torque reaches the judgment value is met, and the time is greater than the Tn118 set
time, the INT signal is output.
Summary of Contents for JSDG2S Series
Page 1: ......
Page 44: ...2 5 400V Class...
Page 303: ...5 178 2 3 1...
Page 693: ...10 7 10 2 Servo Drive Dimension 1 JSDG2S 10A 15A E 200V Class 2 JSDG2S 20A 30A E 200V Class...
Page 694: ...10 8 3 JSDG2S 10A 15A EL 200V Class 4 JSDG2S 20A 30A EL 200V Class...
Page 695: ...10 9 5 JSDG2S 10A 15A L 200V class 6 JSDG2S 20A 30A L 200V Class...
Page 700: ...10 14 Up to 130 Frame Series Up to 220 Frame Series...
Page 704: ...10 18 Up to 220 Frame Series Up to 130 Frame Series LL Without brake LL With brake IH Series...
Page 713: ...11 1 Chap 11 Appendix 11 1 Manual Revision History 11 2...
Page 718: ......