7-40
Cn036 ID Setting
【
8-1
】
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
1 -- 1
~
254
★
--
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
0027H
2024H
2024H
O O O O O
Setting Description: When using the Modbus Communication Interface, each set of Drivers needs to set different IDs in
this parameter in advance; if the IDs are set repeatedly, it will result in communication not being
operated normally.
Cn037.0
Modbus RS-485 Communication Transmission Rate
【
8-1
】
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
1 --
0
~
5
★
--
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
0028H
2025H
2025H
O O O O O
Setting Description:
Setting
Description
Setting
Description
0 4800
bps 3 38400
bps
1 9600
bps 4 57600
bps
2
19200 bps
5
115200 bps
Cn037.2 RS-485 Communication Write Selection
【
8-1
】
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
1 --
0
~
1
★
--
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
0028H
2025H
2025H
O O O O O
Setting Description:
Setting
Description
0
RS-485 Communication Write to EEPROM
1
RS-485 Communication Write to SRAM
Cn038.0 Protocol
【
8-1
】
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
0 --
0
~
8
★
--
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
0029H
2026H
2026H
O O O O O
Summary of Contents for JSDG2S Series
Page 1: ......
Page 44: ...2 5 400V Class...
Page 303: ...5 178 2 3 1...
Page 693: ...10 7 10 2 Servo Drive Dimension 1 JSDG2S 10A 15A E 200V Class 2 JSDG2S 20A 30A E 200V Class...
Page 694: ...10 8 3 JSDG2S 10A 15A EL 200V Class 4 JSDG2S 20A 30A EL 200V Class...
Page 695: ...10 9 5 JSDG2S 10A 15A L 200V class 6 JSDG2S 20A 30A L 200V Class...
Page 700: ...10 14 Up to 130 Frame Series Up to 220 Frame Series...
Page 704: ...10 18 Up to 220 Frame Series Up to 130 Frame Series LL Without brake LL With brake IH Series...
Page 713: ...11 1 Chap 11 Appendix 11 1 Manual Revision History 11 2...
Page 718: ......